7
3. Close store operation (PGM2 mode) — master and satellite
When the close store operation is performed at the master, the IRC system is closed and the
registration function becomes unavailable at all the machines in the IRC system. It should be
noted that for the close store operation, all the satellites must be in their SIGN-OFF state. After
this operation, the communications between the master and satellites which have been enabled
with the open store operation are disabled. The master, however, can download preset data and
reset the sales data at satellites.
In the close store state, key operations in the REG or MGR mode is invalid.
Select “CLOSE STORE” from the PGM2 MODE window
and touch the 
ENTER
 key.
NOTE
You can also perform the close store operation at each satellite. Once the close store
operation is performed at a satellite, you can no longer make registrations at the satellite.
If a satellite is in the SIGN-ON state, the master locates this error and displays the machine
number of the corresponding satellite.
When the close store operation is performed, the data remaining in the T-LOG buffers of all
the satellites is collected by the master.
If a transmission error occurs during the close store operation, the master displays and prints
(journal printer) the machine number of the satellite that has encountered the error.
In this case, a prompt to attempt a retry is displayed when the system retry has been enabled.