UP-3301 (serv.man4). Installation Manual (Version B Above) - Sharp EPOS Service Manual (repair manual). Page 13

Read Sharp UP-3301 (serv.man4) Service Manual online

UP-3301V
Built-in Printer: UP-T80BP
– 11 –
13. Connect the Printer cables to the CONTROL PWB.
1) SWITCH UNIT CABLE 
I
: Connect to the CN7.
3) AUTO CUTTER RELAY PWB CABLE 
L
: Connect to the CN4.
4) MOTOR CABLE 
Q
: Connect to the CN2.
5) SENSOR CABLE 
R
: Connect to the CN6.
6) I/F CABLE 
8
: Attach the Ferrite core 
[
.
Fig. 8
14. Routing for each cables as shown below
Fig. 9
15. Install the BOTTOM PLATE 
2
2
2
2
.
Fig. 10
16. Install the PRINTER COVER 
Y
Y
Y
Y
.
Fig. 11
2) HEAD CABLE 
O
: Connect to the CN5.
Attach the FERRITE CORE 
V
 and CABLE
CLAMP 
4
.
Fix the CABLE CLAMP 
4
 with a SCREW 
X
.
26
22
13
21
16
19
4
28
: XEBSD30P08000
28
26
31
22
13
21
16
19
27
28
8
2
1
29