UP-3300 (serv.man17). Option Installation Manual - Sharp EPOS Service Manual (repair manual). Page 13

Read Sharp UP-3300 (serv.man17) Service Manual online

1. LIST FOR SCREWs
No.
PARTS CODE
M [mm]
L [mm]
K
XEBSD30P08000
3
8
Z
X
S
-
a
XEBSD26P06000
2.6
6
S
-
b
S
-
c
XEBSD26P08000
2.6
8
S
-
d
7
XHBSD30P06000
3
8
U
2. INSTALLATION OF PAPER NEAR END SENSOR 
[PARTS LIST]
No.
PARTS NAME
PARTS CODE
NOTE
1
PAPER NEAR
END SENSOR
DUNTK3819BHZZ
SENSOR UNIT,
FIXING SCREW
2
NEAR END
SENSOR
CONNECTOR
QCNCM6865RC0B
2 pin connector
1. Remove the BOTTOM PLATE .
2. Remove the PS+CONTROL PWB .
3. Solder the CONNECTOR 
1
 to the PS+CONTROL PWB (No.
CN1)
4. Install the NEAR END SENSOR UNIT 
2
 to the CABINET , and
fix it with the fixing SCREW 
3
.
Fig. 12
16. SRN I/F: STANDARD
1) Connect to the SRN cable 
1
 to the SRN connector 
2
.
2) Install the Ferrite core 
3
 to the SRN cable 
1
.
3) Install the Nylon band 
4
 to the SRN cable 
1
.
*
Connect the terminal resistor (50 ohm: QCNCM7145RCZZ) to the
POSs at both ends and in front of the SRN in-line system.
17. RS232 I/F: STANDARD
1) Connect the RS232 cable 
1
 to the connector.
2) Install the ferrite Core 
2
 to RS232 cable.
3) Install the ferrite core 
3
 to the cables.
L
M
L
M
1
3
2
– 12 –
Page of 14