ER-A880 (serv.man2). ERA850 880 Service Manual - Sharp EPOS Service Manual (repair manual). Page 10

Read Sharp ER-A880 (serv.man2) Service Manual online

Always short 1 and 2 of jumper switch JP1 on the main PWB.
2
When the Branch Trunk Network and Two ECR’S are
Available.
a) Connecting terminals
Both ends of the network must be terminated with a 50
 terminator. If
only two active terminals are tested and left on the network, discon-
nect all other terminals from the network. (In this case as well, both
ends of the trunk network must be terminated with 50
).
Fig. 7 Terminal connection
b) Receive level adjustment
i)
Turn on both the receiver terminal and the transmitter terminal.
ii) Run the diagnostic program "Flag send check" on the transmitter
terminal to send a flag.
iii) Checking transmitter terminals’ output waveform
Using an oscilloscope, check the transmitter terminal’s output sig-
nal waveform.
Fig. 8 Transmitter terminal’s output waveform
(at transmitter output)
At the receiver terminal, the transmitter terminal’s output waveform
is subject to attenuation and distortion due to the length of the
trunk cable (this depends on the characteristics of the cable itself).
Fig. 9 Example of distorted signal waveform at the receiver terminal
(RG58/U 400m)
Adjust the receiver terminal adjust VR3 (5k
) on the main PWB
until the waveform as shown in Fig. 10 is obtained at TP (pin 1 of
the 75115). (For the location of VR3, see Fig. 6 Board location of
this subsection).
Clockwise rotation of VR3 extends the High level pulse width of
the signal at TP (pin 1 of the 75115).
Fig. 10 Waveform at TP (pin 1 of the 75115 IC in the receiver
terminal)
5) Other Checks (These Checks should be done
After the Receive Level Adjustment is
Completed).
1
 Line driver bias control circuit
Make sure that the voltage at the 
A
-side lead of the  R3 resistor
(150
, 3W) shown in Fig. 6 is properly switched.
Procedure:
i)
Connect a terminating resistor or read network to the BNC con-
nector, QCNW-6856RCZZ (Fig. 2).
ii) Run the diagnostic program "Data send check", and make sure
that the voltage at point 
A
 (in Fig. 6) is switched as shown in
Fig. 11.
Fig. 11 bias circuit switching waveform
iii) If the waveform as shown in Fig. 11 is not obtained, it is most
probable that transistor Q5 (2SC4699) is defective.
2
For the other check items, refer to DIAGNOSTICS
SPECIFICATIONS
Main PWB
Chi
p
s
VG
A
 c
o
n
tr
o
lle
r
JP1
IC
28
ER-A850/A880
R50 
R50 
ER-A850/880
1µ S
1µ S
3.8V
0.8V
1µ S
1µ S
12V
0V
4.3ms
17ms
– 8 –
Page of 92