7. Backlight characteristics
The backlight specifications are under the following conditions.
1) Rating (Note)
Item
Min.
Standard
Max.
Unit
Brightness
40
65
cd/m
2
2) Lamp: FLE-30164C(FA)B-NS115  1 pc.
2-1. Rating (1 pc.)
Item
No conductors
around
Max.
allowance
Circuit voltage
(VS) 1000 V Min.
1500 V
Discharge lamp current
(IL) 5 mA Typ.
7 mA
*
Power consumption
(P) 1.7 W
Discharge lamp voltage
(VL) 340 V
Brightness
(B) 27000 cd/m
2
 Typ.
*
The CCFT backlight heat may deteriorate the display quality. The
advisable tube current is, therefore, 5mA or less. 
2-2 Life time
10,000 hours at rated current 5mA. 
However, the following invertor conditions must be satisfied.
Positive waveforms and negative waveforms are symmetrical to
each other. No spike waveforms. Must be sine waveforms.
The secondary generation voltage is 1000V or above. 
The life is determined when one or two of the following items is or are
satisfied. (25°C 
±
5°C)
a) The discharge start voltage reaches 10.8V.
b) The illumination or light quantity (radiating illumination) reaches
50% of the initial value. 
Note: The rating value is the average brightness of five measurement
points (1 
 5) in the effective display area shown in Fig. 11.
Fig. 11 Measurement point (1 
 5)
8. Unit handling
8-1. Unit installing angle
The unit has the view angle characteristics as shown in Fig. 12. 
θ
y
MIN.
 < View angle range < 
θ
y
MAX.
(For the values of 
θ
y
MIN.
 and 
θ
y
MAX.
, refer to Fig. 12.)
Fig. 12 Dot matrix LCD view angle
8-2. Unit installation 
Install the unit following the precautions in 8-3 without applying unnec-
essary load to the LCD cells and the LSIs. (Be careful not to warp or
twist them.)
8-3. Note for installation
(1) The surface of polarizing plate is susceptible to damage. Be care-
ful to handle it. 
(2) When the LCD panel surface is dirtied, clean it with cotton or soft
cloth.
(3) If water drop is attached for a long time, it may cause stain or
discoloration. Remove it immediately.
(4) Be careful to handle the LCD panel (glass). Be careful not to drop
it or hit with a hard material. 
(5) This unit uses the COMS LSI. Be careful to static electricity, and
provide human body grounding. 
8-4. Others
(1) Do not leave the unit under the direct sunlight and under strong
ultraviolet rays for a long time.
(2) The internal liquid crystal may be solidified to break cells under the
temperature below the rated storage temperature. Under the tem-
perature above the rated storage temperature, the liquid crystal
may be liquified not to return. Be sure to store it under normal
temperature, normal humidity, and dark place. 
(3) If the LCD is removed from the unit, contact failure may be
caused. Do not disassemble it. 
9. Lot No. 
The lot No. is as shown below:
(Example)
94
A
00001
( )
 Manufacturing factory (Alphabet)
 Serial No. (Missing No. exits.)
 Month of production (A=January,
 B=February, ... L=December)
 Year of production 
dot
1
2
3
4
5
160
320
480dot
120
240
360
Effective display area
-
Θ
y
View angle direction +
Θ
y
Θ
y=0˚ (Normal direction)
(Panel surface)
– 84 –
Page of 92