ER-A771 (serv.man3). Service Manual - Sharp EPOS Service Manual (repair manual). Page 10

Read Sharp ER-A771 (serv.man3) Service Manual online

ER-A771VS
SERVICE PRECAUTION
3 – 2
6
Connect P.C. and ER-A771 (CH2) via RS232. (Fig 1)
7
Execute "POSUTILITUTOOL.EXE" on P.C.
*Don't execute the other Software at the same time.
8
Select the ROM object Files by "Add Files.." button.
9
Push "SEND" button.
Program data is sent to ER-A771 automatically.
9
Program data is received from P.C. automatically.
ER-A771 shows
10
When sending is completed,
the initial Window is shown after "Complete" window.
10
ER-A771 shows
"Completed."
11
Turn OFF the power.
12
Select "Normal Mode".
Set "IPL switch" to "OFF".
(Ref. Hardware manual)
13
Execute "Service Reset" on ER-A771.
No
Procedure on P.C. side
No
Procedure on ER-A771 side
IPL from IR
Connected IRDA 115200
21 22 23 24 25 26 27 28
IPL from Serial I/O
Connected IRDA 115200
21 22 23 24 25 26 27 28
29 2A 2B 2C 2D 2E 2F
Completed.
IPL from Serial I/O
Connected IRDA 115200
30 31 32 33 34 35 36 37
38 39 3A 3B 3C 3D 3E 3F
Completed.