ER-A750 (serv.man5). ERA750 Programming Manual - Sharp EPOS Service Manual (repair manual). Page 22

Read Sharp ER-A750 (serv.man5) Service Manual online

906-D:
1.Presetting of consective No.
2.Fractional quantity
1.Presetting of
consective No.
2.Fractional quantity
906-D
Disable
No
0
Yes (3 digit decimal place)
1
Enable
No
2
Yes (3 digit decimal place)
3
[JOB#907] : MRS=0014
907-A:
1. Entry of SCM(+)/(–) after registration in REG/MGR mode
2. SCM input compulsory
1. Entry of SCM(+)/(–)
after registration in
REG/MGR mode
2. SCM input compulsory
907-A
Disable
Non-compulsory
0
Compulsory for an
individual clerks
1
Compulsory for all clerks
2
Enable
Non-compulsory
4
Compulsory for an
individual clerks
5
Compulsory for all clerks
6
SCM : Starting Cash Memory
907-B:
Not used ( Fixed at "0" )
907-C:
1. In case of all clerk CCD, X report before CCD entry
2. Locking of REG mode entry after individual clerk
3. Minus Department and PLU
1. In case of all
clerk CCD, X
report before
CCD entry
2. Locking of
REG mode
entry after
individual
clerk
3. Minus
Department
and PLU
907-C
Disable
Disable
Disable
0
Enable
1
Enable
Disable
2
Enable
3
Enable
Disable
Disable
4
Enable
5
Enable
Disable
6
Enable
7
907-D:
1. Z-counter print for PLU, Hourly, Clerk, Daily net, GLU
2. CCD compulsory
1. Z-counter print for
PLU, Hourly, Clerk,
Daily net, GLU
2. CCD compulsory
907-D
Yes
Non-compulsory
0
Compulsory for an
individual clerks
1
Compulsory for all clerks
2
No
Non-compulsory
4
Compulsory for an
individual clerks
5
Compulsory for all clerks
6
[JOB#908] : MRS=0000
908-A:
GT print on Z report
GT1 (NET)
GT2 (+)
GT3 (–)
908-A
Print
Print
Print
0
Skip
1
Skip
Print
2
Skip
3
Skip
Print
Print
4
Skip
5
Skip
Print
6
Skip
7
908-B:
GT print on X report
GT1 (NET)
GT2 (+)
GT3 (–)
908-B
Skip
Skip
Skip
0
Print
1
Print
Skip
2
Print
3
Print
Skip
Skip
4
Print
5
Print
Skip
6
Print
7
#908-C: 1. Add void-mode transaction data to hourly total report
2. X1/Z1 report in X2/Z2 mode
3. Resetting of consecutive number in Z1 resetting
1. Add void-
mode
transaction
to hourly
total report
2. X1/Z1 report
in X2/Z2
mode
3. Resetting of
consecutive
No.in Z1
resetting
908-C
No
Enable
No
0
Yes
1
Disable
No
2
Yes
3
Yes
Enable
No
4
Yes
5
Disable
No
6
Yes
7
908-D:
1.Printing of X/Z report
2.Z1 resetting that resets GT
1.Printing of X/Z report 2.Z1 resetting that resets GT
908-D
Receipt & Journal
Disable
0
Enable
1
Journal only
Disable
4
Enable
5
– 20 –
Page of 47