ER-A750 (serv.man5). ERA750 Programming Manual - Sharp EPOS Service Manual (repair manual). Page 20

Read Sharp ER-A750 (serv.man5) Service Manual online

2. [2 SYSTEM PRESET]
DISPLAY: Setting item select screen
Select “1 SYSTEM PRESET” and press the ENTER key.
DISPLAY: SYSTEM RESET screen 1/3
                 
 “PAGE DOWN” key
DISPLAY: SYSTEM RESET screen 2/3
                 
 “PAGE DOWN” key
DISPLAY: SYSTEM PRESET screen 3/3
Select the job # to be changed and enter the value.
The content of each jog is described below. 
[JOB #901]:MRS=0102
#901-A: Not used (Fixed at "0")
#901-B: Tax system
1. TAX system
901-B
Auto TAX 1~6
0
Auto VAT 1~6
1
Manual VAT 1~6
2
Manual VAT 1
3
Manual TAX 1~6
4
Auto VAT 1~3 and Auto TAX 4~6
5
#901-C: 1. Rounding system
1. Rounding system
901-C
Normal
0
SWEDEN
1
DENMARK
4
901-D:
1.TAB setting
1.TAB setting
901-D
0.0
1
0.00
2
0.000
3
[JOB#902] : MRS=0000
902-A:
1.In-line system
1.In-line system
902-A
No
0
Yes
1
902-B,C: Not used (Fixed at “00”)
902-D:
1.EFT terminal
2.Clerk key
1.EFT terminal
2.Clerk key
902-D
No
7 bit
0
8 bit
2
Yes
7 bit
4
8 bit
6
– 18 –
Page of 47
Display