XE-A303 (serv.man4). XE-A303 Service Manual - Sharp ECR Service Manual (repair manual). Page 7

Read Sharp XE-A303 (serv.man4) Service Manual online

XE-A303 (V)
OPTIONS
– 4 –
8. USB PORT
[DEVICE]
USB B Type
[OUTLINE]
This ECR has 1 port.
This is used in order to connect with a personal computer.
[SPECIDICATIONS]
1) Transmission rate
USB 2.0 Full Speed Max. 12Mbps 
2) Connector
USB B Type 
3) Pin assign
1Pin 5V 
2Pin -D 
3Pin +D 
4Pin GND
9. BATTERY
9-1. MEMORY BACK UP BATTERY
CHAPTER 2. OPTIONS
1. OPTIONS (NO)
2. SERVICE OPTIONS (NO)
3. SUPPLIES
4. SPECIAL SERVICE TOOLS  (NO)
CHAPTER 3. MASTER RESET AND PROGRAM RESET
1. MASTER RESETTING
Master resetting clears the entire memory and resumes initial values.
Master resetting can be accomplished by using the following procedure:
The master reset can also be accomplished in the following case.
In case power failure occurs when the machine has no battery
attached to it, the master reset operation is automatically performed
after the power has been plugined the AC cord to the wall outlet.
(This is because if power failure occurs with no battery attached to
the machine, all the memories are lost and the machine does not
work properly after power recovery; this requires the master reset
operation.)
2. PROGRAM RESETTING (INITIALIZATION)
This resetting resumes the initial program without clearing memory.
This resetting can be operated at below sequence in PGM mode.
Note: In case power failure occurs when the machine has no battery
attached to it, the master reset operation is automatically per-
formed after the power has been restored.
2
1
3
4
11.0
12.04
2.5
Type:
Rechargeable battery
Number of battery:
1 pcs as standard
NO
NAME
PARTS CODE
PRICE RANK
DESCRIPTION
1
Thermal roll paper
TPAPR6645RC05
BA
5 ROLLS/PACK 
Procedure A: 1) Unplug the AC cord from the wall outlet.
2) Set the mode switch to the PGM position.
3) While holding down both the JOURNAL FEED key
and [CL] key, plugin the AC cord to the wall outlet.
Procedure: 1) Unplug the AC cord from the wall outlet.
2) Wait over 1 muinite for discharging.
3) Set the mode switch to the PGM position.
4) While holding down both JOURNAL FEED key, plugin
the AC cord to the wall outlet.
Page of 32