XE-A303 (serv.man4). XE-A303 Service Manual - Sharp ECR Service Manual (repair manual). Page 5

Read Sharp XE-A303 (serv.man4) Service Manual online

XE-A303 (V)
SPECIFICATIONS
– 2 –
The mode switch has these settings:
5. DISPLAY
5-1. OPERATOR DISPLAY
Layout:
5-2. CUSTOMER DISPLAY
Layout:
Operator display
•  Clerk code or Mode name
The mode you are in is displayed. When a clerk is assigned, the clerk
code is displayed in the REG or OP X/Z mode. For example, “
*
01
*
is displayed when clerk 01 is assigned.
• Repeat
The number of repeats is displayed, starting at “2” and incremental
with each repeat. When you have registered ten times, the display will
show “0” (2 
3
 3......9 
3
 0 
3
 1 
3
 2...)
• Sentinel mark
When amount in the drawer reaches the amount you prepro-
grammed, the sentinel mark “X” is displayed to advise you to remove
the money and put it in a safe place.
•  Power save mark
When the cash register goes into the power save mode, the power
save mark (decimal point) lights up.
•  Function message display area
Item labels of departments and PLU/subdepartments and function
texts you use, such as %1, (-) and CASH are displayed.
When an amount is to be entered or entered, “AMOUNT” is dis-
played: When an amount is to be entered, ------- is displayed at the
numeric entry area with “AMOUNT”. When a preset price has been
set, the price is displayed at the numeric entry area with “AMOUNT”.
•  Numeric entry display area
Numbers entered using numeric keys are displayed here.
Date and time display
Date and time appear on the display in the OP X/Z, REG, or MGR
mode. In the REG or MGR mode, press the [#/TM/SBTL] key to dis-
play the date and time.
Error message
When an error occurs, the corresponding error message is displayed
in the function message display area.
Customer display (Pop-up type)
q
:
This mode locks all register operations. (AC power turns off.)
No change occurs to register data.
OP X/Z: To take individual clerk X or Z reports, and to take flash
reports.
It can be used to toggle receipt state “ON” and “OFF” by
pressing he [RCP/PO] key.
REG:
For entering sales.
PGM:
To program various items.
p
:
Enters into the void mode. This mode allows correction after
finalizing a transaction.
MGR:
For manager’s entries. The manager can use this mode for an
override entry.
X1/Z1:
To take the X/Z report for various daily totals.
X2/Z2:
To take the X/Z report for periodic (weekly or monthly) consol-
idation.
Display device:
LCD
Number of line:
2 line
Number of positions: 16 positions/line
Color of display:
Yellow Green, Orange
Character form:
5 x 7 dots
Character size:
9.7 (H) x 4.8 (W) mm
Display device:
LED
Number of line:
1 line
Number of positions: 7 positions
Color of display:
Yellow Green
Style:
Pop up type
Character form:
7 segment + Dp
Character size:
14.2mm (H) x 7.9mm (W)
Function message display area
Clerk code or mode name
Numeric entry display area
Receipt OFF indicator
Repeat / Sentinel mark / Power save mark
Power save mark
(Lighting the mark only under the power save mode)
Page of 32
Display

Click on the first or last page to see other XE-A303 (serv.man4) service manuals if exist.