XE-A213 (serv.man4). XE-A213 Service Manual - Sharp ECR Service Manual (repair manual). Page 13

Read Sharp XE-A213 (serv.man4) Service Manual online

XE-A203V/A213V
HARDWARE DESCRIPTION
– 11 –
7-2-3.MODE KEY (203V/213V)
7-3. NORMAL/FLAT KEY (203V/213V) JUDGMENT 
METHOD
When J1 on the main PWB is shorted, the main PWB supports NORMAL KEY.
When J1 is opened, the main PWB supports FLAT KEY.
8. USB I/F
The USB CONTROLLER (SATELLITE) is built in the CPU (M30245).
USB specifications
1) USB2.0 FULLSPEED
2) Self power
Related port
9. POWER/ RESET
9-1. POWER COMPOSITION
9-2. OPERATION WHEN POWER ON/OFF
When the mode key is in the OFF position, all the power lines except for
the battery backup line in the ECR are turned OFF. 
9-3. MASTER RESET
When the power is turned ON without a battery, master reset is per-
formed.
10. PRINTER CONTROL
10-1. STEPPINGMOTOR CONTROL
The 2-phase bi-polar stepping motor is driven at a constant voltage with
SANYO-make LB1838M.
1step: 0.087mm, 1dot: 2step
Related port
DriveSTEP
Function
Signal 
name
CPU
PORT
Remark
Vbus detection
signal
Vbus-
DTCT
-
Connected to the USB connector
VBUS.
USB IF power 
input
Uvcc
-
3.3V same as the CPU power
(battery backup line) is inputted.
USB signal
USB D+
-
USB signal
USB D-
-
Low pass filter
LPF
-
Used for use of the frequency syn-
thesizer and for forming an exter-
nal filter.
U S B   c o n n e c -
tion detection 
ATTACH
P90
Connected to USB D+ via 1.5 k
Ω. 
(ATTACH/DETACH function 
enabled)
FOR KEY I/F BOARD
MODE SWITCH
CN1
P: 2.0mm HOLE ONLY
8
9
10
11
12
13
5
1
7
2
4
6
3
SW1
GND
/VON
GND
/RESET
/S0
/S1
/S2
MOR
/S3
/S4
/S5
/S6
/S7
0
000
00
1
2
3
4
5
6
7
8
9
10
PORT
Signal name
P104
AN4
ENA1
P105
AN5
ENA2
P106
AN6
IN1
P107
AN7
IN2
Driver IC input (CPU output)
Motor drive signal
STE
P
IN1
IN2
ENA1
ENA2
A
(OUT1)
B
(OUT3)
/A
(OUT2)
/B
(OUT4)
1
L
L
H
H
H
H
L
L
2
H
L
H
H
L
H
H
L
3
H
H
H
H
L
L
H
H
4
L
H
H
H
H
L
L
H
LM2574 
+ Tr. 
VLED
24V DRAWER
5V 
VP (8V) 
Blackout detection point
Blackout 
detection 
point
TRANS
PQ1CG203
PQ1CG203
ON/OFF control 
(MODE SW OFF position, Blackout, 
control by CPU P83 )
BA00AS
UPC29M33
3.3V 
BH33FB1 
AC
ON/OFF control 
(MODE SW OFF position) 
Battery 
(Unit 3 x 3)
LCD backlight
Reset IC
Reset signal
Forced reset 
( MODE SW SRV 'position)
PRINTER
Winding motor
Page of 34
Display

Click on the first or last page to see other XE-A213 (serv.man4) service manuals if exist.