Read Sharp XE-A213 (serv.man3) Service Manual online
XE-A203/A213
PROGRAM MODE
2 – 8
[JOB#14] THE TIME (HOUR ONLY) OF EXCHANGING THE
CURRENCY BETWEEN LOCAL AND EURO -- XX --
MRS = 00
XX : Hour (00-23)
[JOB#15] (Only for A213V)
FUNCTION SELECT2
-- ABCDEFGH --
MRS = 00011010
[JOB#35] USB Communication TIME OUT -- XXX --
MRS = 007
XXX: Time out time (1 - 255 sec)
[JOB#50] THERMAL PRINTER DENSITY CONTROL -- XX --
MRS = 50
XX: density (00-99)
00 : 70 % for standard
50 : 100 % (Standard density)
99 : 130 % for standard
50 : 100 % (Standard density)
99 : 130 % for standard
[JOB#61] OTHERS1 PROGRAMMING -- ABCDEFGH --
MRS = 00100112
[JOB#62] OTHERS2 PROGRAMMING -- ABCDEFGH --
MRS = 01000000
A: PLU SHIFT LEVEL reset
A
AUTO
0
★
MANUAL
1
B: PLU LEVEL SHIFT
B
REG & MGR
0
★
MGR only
1
C: PLU SHIFT LEVEL AUTO reset timing
C
1 item
0
★
1 receipt
1
(This setting is available in case "PLU SHIFT LEVEL reset = AUTO")
D: Checking of CLERK# on guest check when
a reorder is made
D
Yes
0
No
1
★
E: Printing of PB/NBAL on G.C.RCPT
E
Yes
0
No
1
★
F: Clear details in GLU buffer at NBAL
F
No
0
★
Yes
1
G: Clear details in GLU buffer at BILL (G.C.RCPT)
print
G
No
0
Yes
1
★
H: Not used (Fixed at “0”)
A, B: Not used (Fixed at “00”)
C: Programming of MINUS dept/PLU
C
Disable
0
Enable
1
★
D: Fractional treatment
D
Round off (4-DOWN, 5-UP)
0
★
Raising to unit
1
Disregarding
2
E: 00 key or 000 key selection for 00 key position
E
00 key
0
★
000 key
1
F: Time format
F
12hour 0
24hour
1
★
G: Date format
G
M-D-Y 0
D-M-Y
1
★
Y-M-D
2
H: TAB
H
0
0
1
1
2
2
★
3
3
A: Not used (Fixed at “0”)
B: ERROR BEEP for missoperation
B
LOCK ERROR
0
MISSOPERATION
1
★
C: Key catch sound
C
Yes 0
★
No
1
D: Buffered Keyboard
D
Yes 0
★
No
1
E: VOID mode
E
Enable 0
★
Disable
1
F: Printing of VOID MODE in X2/Z2 report
F
Yes 0
★
No
1
G: Printing of VOID MODE in X1/Z1 report
G
Yes 0
★
No
1
H: Addition to the hourly total in VOID MODE
H
No
0
★
Yes 1