PROGRAM MODE
2 – 12
13) TEXT CHANGING (TO DEFAULT TEXT)
X: 0 = English text
1 = German text
2 = French text
3 = Spanish text
2 = French text
3 = Spanish text
MRS = 0
When this job is executed, below texts are set as default data.
(a) Function text
(b) Each message text (LOGO,etc..)
(c) Clerk name
(b) Each message text (LOGO,etc..)
(c) Clerk name
(Sample)
14) RESETTING OF ALL COUNTER & TOTALIZER
All counter, totalizer, all GTs, and all Z counter are reset.
(Sample)
15) CHANGING MEMORY TYPE
(EJ RECORD AND PLU RECORD)
X : 0 = TYPE1 (EJ:8000 records and PLU 1200 records)
1 = TYPE2 (EJ:9000 records and PLU 210 records)
MRS = 1
When this job is executed, EJ records are deleted and PLU records are
set the default data after deleted all records even if same memory type
is entered.
set the default data after deleted all records even if same memory type
is entered.
(Sample)
XE-A203V:
XE-A213V:
X
88
0
ST
TL/NS
#/TM/ST
X
88
0
TL/NS
0
05/02/2006 123456#123456
12:34PM 01 M.KLERK
*PGM*
#88
HEADER
DATE/MACHINE NO./CC-NO.
TIME/CLERK NO/CLERK NAME
TIME/CLERK NO/CLERK NAME
MODE TITLE
LANGUAGE MODE
LANGUAGE MODE
XE-A203V:
XE-A213V:
XX
89
#/TM/ST
TL/NS
ST
XX
89
TL/NS
05/02/2006 123456#123456
12:34PM 01 M.KLERK
*PGM*
#89
HEADER
DATE/MACHINE NO./CC-NO.
TIME/CLERK NO/CLERK NAME
TIME/CLERK NO/CLERK NAME
MODE TITLE
JOB#
JOB#
XE-A203V:
XE-A213V:
X
90
#/TM/ST
TL/NS
ST
X
90
TL/NS
05/02/2006 123456#123456
12:34PM 01 M.KLERK
*PGM*
#90
HEADER
DATE/MACHINE NO./CC-NO.
TIME/CLERK NO/CLERK NAME
TIME/CLERK NO/CLERK NAME
MODE TITLE
MEMORY TYPE (0:TYPE1, 1:TYPE2)
MEMORY TYPE (0:TYPE1, 1:TYPE2)
0