XE-A212 (serv.man7). Latest FAQ's - Sharp ECR FAQ (repair manual). Page 2

Read Sharp XE-A212 (serv.man7) FAQ online

 
 
Q. How do I program a PLU with Description, Price and Department? 
 
A.  Using the MA Key, turn the Key to PGM mode. 
 
    Press the PLU you wish to program 
    Press the 00 key 
    Type the PLU Name 
    Press ST 
    Enter the PU Price 
    Press ST 
    Enter the Department Number 
    Press ST 
    Press TL to save 
 
 
 
 
Q. How do I set Zero Skip on PLU reports to save paper? 
 
A. Using the MA key, turn the key to PGM 
 
    Press ST 
    Enter 6 
    Press X 
    Enter 11000111 
    Press ST 
    Press TL 
 
 
 
Q. How do I specify a clerk to be in training mode? 
 
    A  Using the MA key, turn the key to PGM mode 
 
    Press ST 
    Enter 86 
    Press X 
    Enter 1 (1 = Clerk number, can be changed to any clerk number) 
    Press ST 
    Press TL 
 
 
Q. How do I prevent the Refund key working in REG mode? 
 
A Using the MA key, turn the key to PGM mode. 
 
Press ST 
Enter 5 
Press X 
Enter 00000100 
Press ST 
Press TL 
 
 
Q. How do I make a PLU an open entry type? 
 
A. Using the MA key, turn the key to PGM mode 
     
    Press the PLU (that you wish to change) 
    Press ST 
    Press ST 
    Press ST 
    Press 00 (until subdept is shown) 
    Press ST 
    Press TL 
 
 
 
Page of 6