XE-A201 (serv.man4). Service Manual - Sharp ECR Service Manual (repair manual). Page 3

Read Sharp XE-A201 (serv.man4) Service Manual online

XE-A201VS  SPECIFICATIONS
– 2 –
The mode switch has these settings:
q
:
This mode locks all register operations. (AC power turns off.)
No change occurs to register data.
OP X/Z: To take individual clerk X or Z reports, and to take flash
reports.
It can be used to toggle receipt state “ON” and “OFF” by
pressing he [RCP/PO] key.
REG:
For entering sales.
PGM:
To program various items.
p
:
Enters into the void mode. This mode allows correction after
finalizing a transaction.
MGR:
For manager’s entries. The manager can use this mode for
an override entry.
X1/Z1: To take the X/Z report for various daily totals.
X2/Z2: To take the X/Z report for periodic (weekly or monthly) con-
solidation.
5. DISPLAY
1) OPERATOR DISPLAY
Display device
: LED numeric display
Number of line
: 1 line
Number of positions : 10 positions numeric display
Color of display
: Yellow / Green
Character form
: 7 segment + DP
Character size
: Numeric 14.2 (H) x 7.9 (W) mm
Layout:
2) CUSTOMER DISPLAY
Display device
: LED
Number of line
: 1 line
Number of positions : 7 positions
Color of display
: Yellow / Green
Style
: Pop up type
Character form
: 7 segment + Dp
Character size
: 14.2mm (H) x 7.9mm (W)
Layout:
Amount: Appears in the far-right eight (max.) positions. When the
amount is negative, the minus symbol "-" appears before the
amount.
Number of repeats for repetitive registrations:
The number of repeats is displayed, starting at "2" and incre-
mental with each repeat. When you have registered ten times,
the display will show "0." (2 
3
 3 .... 9 
3
 0 
3
 1 
3
 2 ... )
Receipt function status:
The indicator "_" appears in the RCPT OFF position when the
receipt function is in the OFF status.
Time:
Appears in the second to sixth positions (using 24-hour for-
mat) in the OP X/Z, REG or MGR mode. In the REG or MGR
mode, press the [#/TM/ST] key to display the time.
Machine state symbols
:
Appears during programming.
:
Appears when an error is detected.
:
Appears when the subtotal is displayed or when the amount
tendered is smaller than the sales amount.
:
Appears when the [EX] key is pressed to calculate a subtotal in
foreign currency.
:
Appears when a transaction is finalized by pressing the [TL/
NS], [CH], [CR1] or [CR2] key.
:
Appears when the change due amount is displayed.
Appears in the far-left three positions at the timing of key entry
when the electronic journal (EJ) memory is full. (Depending on
programming.)
:
Appears when the voltage of the installed batteries is under the
required level. You must replace with new ones within two
days. Refer to page 63 for details.
:
Appears when the batteries are not installed, or the installed
batteries are dead. You must replace with new ones immedi-
ately. Refer to page 63 for details.
:
May appear right below the eighth and ninth places at the tim-
ing of finalization of a transaction when the electronic journal
(EJ) memory is nearly full.
Also appears right below the tenth place when power save
mode is effective.
Appearss when programmed date (and time) for EURO modifi-
cation operation is come.
:
Appears when the print head release lever is in the lifted posi-
tion.
:Appears when the paper is out.
0 . 1 . 2 . 3 . 4 . 5 . 6 . 7 . 8 . 9 .
3 . 4 . 5 . 6 . 7 . 8 . 9 .
Operator display
Customer display (Pop-up type)
PLU/SUB
DEPT REPEAT
RCPT
OFF
NUMBER
SHIFT
DC
Clerk code
Page of 23
Display

Click on the first or last page to see other XE-A201 (serv.man4) service manuals if exist.