XE-A113 (serv.man3). XE-A113 Service Manual - Sharp ECR Service Manual (repair manual). Page 7

Read Sharp XE-A113 (serv.man3) Service Manual online

XE-A113 (V)
OPTIONS
– 5 –
CASE 2:
When numeric entry or item entry is done.
Battery condition will not appeared.
Exceptionally, at the power is restored after power failure, the low bat-
tery condition will appear on the display only when the battery is low.
And the indicator will disappear after any key entry.
[Display sample]
0.00” : Battery is OK.
“L
0.00” : Low battery (You have to change the batteries.)
0.00” : No battery (You have to change the batteries
immediately.)
After finalization
“F
12.34” : Battery is OK.
“L
12.34” : Low battery. (“L” indicate instead of “F”.)
12.34” : No battery. (“L” indicate instead of “F”.)
Note: “NO BATTERY”: When the “NO BATTERY” is display, the master
reset is executed at the timing of “POWER ON”
after the “POWER OFF”.
10. SD MEMORY CARD
[Device]
SD Card (Version. 1.01)
[Outline]
XE-A113 has a SD Memory Card slot.
[Specidications]
CHAPTER 2. OPTIONS
1. OPTIONS (No)
2. SERVICE OPTIONS (No)
3. SUPPLIES
4. SPECIAL SERVICE TOOLS (No)
CHAPTER 3. MASTER RESET AND PROGRAM RESET
1. MASTER RESETTING
Master resetting clears the entire memory and resumes initial values.
Master resetting can be accomplished by using the following procedure:
Procedure A:
1) Unplug the AC cord from the wall outlet or set the
mode switch to OFF Position.
2) Let the ECR be without the memory back up battery.
3) Wait over 1 muinite for discharging.
4) Set the mode switch to any position except OFF.
5) Plugin the AC cord to the wall outlet or turn the mode
switch from OFF Position to another position.
6) Insert batteries before carrying out operation after
master resetting.
The master reset can also be accomplished in the following case.
In case power failure occurs when the machine has no battery
attached to it, the master reset operation is automatically performed
after the power has been restored.
(This is because if power failure occurs with no battery attached to
the machine, all the memories are lost and the machine does not
work properly after power recovery; this requires the master reset
operation.)
2. PROGRAM RESETTING
(INITIALIZATION)
This resetting resumes the initial program without clearing memory.
This resetting can be operated at below sequence in PGM mode.
Procedure:
1) Unplug the AC cord from the wall outlet.
2) Wait over 1 muinite for discharging.
3) Set the mode switch to the PGM position.
4) While holding down the FEED key, plugin the AC
cord to the wall outlet.
Note: In case power failure occurs when the machine has no battery
attached to it, the master reset operation is automatically per-
formed after the power has been restored.
1)  Variable clock rate
: 0 - 25 MHZ
2)  Other commands and memory access : 2.7 - 3.6V
3)  Bus Protocol
: SPI Bus
4)  Correspondence capacity
: 32MB - 512MB
5)  Recommended manufacturer
: SanDisk
No.
NAME
PARTS CODE
PRICE RANK
DESCRIPTION
1
Thermal roll paper
TPAPR6645RC05
AY
5roll/pack (80 
φ)
Page of 32