CODE : 00Z
SERVICE MANUAL
CONTENTS
Parts marked with "!" are important for maintaining the safety of the set. Be sure to replace these parts with specified
ones for maintaining the safety and performance of the set.
LEAD-FREE SOLDER MODEL
XEA113VSME
ELECTRONIC
CASH REGISTER
 MODEL
XE-A113
      
(For “V” version)
 LEAD-FREE SOLDER
CHAPTER 1. SPECIFICATIONS  . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1
CHAPTER 2. OPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5
CHAPTER 3. MASTER RESET AND PROGRAM RESET. . . . . . . . .  5
CHAPTER 4. HARDWARE DESCRIPTION . . . . . . . . . . . . . . . . . . . .  6
CHAPTER 5. TEST FUNCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12
CHAPTER 6. CIRCUIT DIAGRAM AND PWB LAYOUT  . . . . . . . . .  15
XE-A113 (V)   LEAD-FREE SOLDER
 LEAD-FREE SOLDER
The PWB’s of this model employs lead-free solder. The “LF” marks indicated on the PWB’s and the Service Manual mean “Lead-Free” solder. The
alphabet following the “LF” mark shows the kind of lead-free solder. 
Example:
(1) NOTE FOR THE USE OF LEAD-FREE SOLDER THREAD
When repairing a lead-free solder PWB, use lead-free solder thread. Never use conventional lead solder thread, which may cause a breakdown or an accident. 
Since the melting point of lead-free solder thread is about 40°C higher than that of conventional lead solder thread, the use of the exclusive-use soldering iron is rec-
ommendable. 
(2) NOTE FOR SOLDERING WORK
Since the melting point of lead-free solder is about 220°C, which is about 40°C higher than that of conventional lead solder, and its soldering capacity is inferior to
conventional one, it is apt to keep the soldering iron in contact with the PWB for longer time. This may cause land separation or may exceed the heat-resistive tem-
perature of components. Use enough care to separate the soldering iron from the PWB when completion of soldering is confirmed. 
Since lead-free solder includes a greater quantity of tin, the iron tip may corrode easily. Turn ON/OFF the soldering iron power frequently.  
If different-kind solder remains on the soldering iron tip, it is melted together with lead-free solder. To avoid this, clean the soldering iron tip after com-
pletion of soldering work. 
If the soldering iron tip is discolored black during soldering work, clean
and file the tip with steel wool or a fine filer. 
5mm
Lead-Free
Solder composition 
code (Refer to the 
table at the right.)
<Solder composition code of lead-free solder> 
Solder composition
Sn-Ag-Cu
Sn-Ag-Bi
Sn-Ag-Bi-Cu
Sn-Zn-Bi
Sn-In-Ag-Bi
Sn-Cu-Ni
Sn-Ag-Sb
Bi-Sn-Ag-P
Bi-Sn-Ag
a
b
z
i
n
s
p
Solder composition code
a
XE-A113 (V)
SPECIFICATIONS
– 1 –
CHAPTER 1. SPECIFICATIONS
1. APPEARANCE
2. RATING
Specifications and appearance subject to change without notice for
improvement.
*1 Use only the USB cable (manufactured by SHARP) supplied with
the XE-A113 for the connection with a PC.
In case you need a new USB cable, order the USB cable manufac-
tured by SHARP Co. Ltd. (Part code: 0GS5422580) for use with the
XE-A113.
3. KEYBOARD
1) KEYBOARD LAYOUT
2) KEY LIST
Keyboard layout
Note: The small characters on the bottom or lower right in each key
indicates functions or characters which can be used for character
entries for text programming. 
Model
XE-A113
Dimensions
350 (W) 
×
 430 (D) 
×
 281 (H) mm
Weight
8 kg
Power source 220V~230V AC, 50/60Hz
Power
consumption
Stand-by 8.8 W
Operating 33 W (max.)
Working
temperature
0 °C to 40 °C (32 °F to 104 °F)
Electronics
LSI (CPU) etc.
Display
Operator display
7-segment display (10 positions)
Customer display
7-segment display (7 positions)
Printer
Type
One-station thermal printer
Printing speed
Approx. 12 lines/second
Printing capacity
24 digits each for receipt and jour-
nal paper
Other functions
Graphic logo printing function
Logo message function
Receipt (ON-OFF) function, com-
pression printing function
Paper roll
Width
: 57.5 
±
 0.5 mm
Max. diam. : 80 mm
Quality
: High quality (0.06 to 0.08 mm thickness)
Cash drawer
4 slots for bill and 5 for coin denominations
Front view
Rear view
Printer
USB port
SD card slot
Operator display
Receipt paper
Keyboard
Drawer lock
Drawer
Printer cover
Customer display 
(Pop-up type)
Mode switch
Power cord
Take-up spool
Print roller 
release lever
Print roller
arm
Inner cover
Paper roll cradle
Paper positioning guides
Accessories
Manager key
2
Operator key
2
Drawer lock key
2
Paper roll
1
Take-up spool
1
USB cable
(0GS5422580) 
*1
1
Customer
support tool
1 disk
Quick Start Guide 1 copy
Instruction manual 1 copy
Type
Normal keyboard
Key position
STD/MAX 53
Key pitch
19 (W) 
×
 19 (H) mm
Key layout
Fixed type
XE-A113 (V)
SPECIFICATIONS
– 2 –
Key names
4. MODE SWITCH
1) LAYOUT
• Rotary type
The mode switch can be operated by inserting one of the two supplied
mode keys - manager (MA) and operator (OP) keys. These keys can be
inserted or removed only in the “REG” or “OFF” position.
The mode switch has these settings:
5. DISPLAY
1) OPERATOR DISPLAY
Layout:
2) CUSTOMER DISPLAY
Layout:
KEY TOP
DESCRIPTION
2
Paper feed key
RA
Received-on account key
RCPT/PO
Receipt print/Paid-out key
p
Void key
ESC/HELP
Escape key/HELP key
EX
Foreign currency exchange key
%1, %2
Percent 1 and 2 keys
RF
Refund key
-
Discount key
y
Multiplication key
n
Decimal point key
CL
Clear key
00, 0~9
Numeric keys
PLU/SUB
PLU/Subdepartment key
DEPT #
Department code entry key
DEPT SHIFT
Department shift key
CLK#
Clerk code entry key
1-17~16-32
Department keys
VAT
Value added tax key
AUTO
Automatic sequence key
CR1, CR2
Credit 1 and 2 keys
CH1, CH2
Cheque 1 and 2 keys
#/TM/ST
Non-add code/Time display/Subtotal key
TL/NS
Total/No sale key
OFF
: This mode locks all register operations. (AC power turns off.)
No change occurs to register data.
:
OP X/Z : To take individual clerk X or Z reports, and to take flash reports.
It can be used to toggle receipt state “ON” and “OFF” by
pressing he [RCPT/PO] key.
REG
: For entering sales.
PGM
: To program various items.
VOID
: Enters into the void mode. This mode allows correction after
finalizing a transaction.
MGR
: For manager’s entries. The manager can use this mode for 
an override entry.
PGM
VOID
OFF
OP
X/Z
REG
MGR
X
1
/Z
1
X
2
/Z
2
OP
MA
Manager key (MA)
Operator key (OP)
OP
MA
X1/Z1:
To take the X/Z report for various daily totals.
X2/Z2:
To take the X/Z report for periodic (weekly or monthly) consol-
idation.
Display device
: LED
Number of line
: 1 line
Number of positions
: 10 positions
Color of display
: Yellow Green
Character form
: 7 segment 
+
 DP
Character size
: 14.2 (H) 
×
 7.9 (W) mm
Display device
: LED
Number of line
: 1 line
Number of positions
: 7 positions
Color of display
: Yellow Green
Style
: Pop up type
Character form
: 7 segment 
+
 Dp
Character size
: 14.2 (H) 
×
 7.9 (W) mm
Amount: Appears in the far-right eight (max.) positions. When the
amount is negative, the minus symbol “-” appears before the
amount.
Number of repeats for repetitive registrations:
The number of repeats is displayed, starting at “2” and incre-
mental with each repeat. When you have registered ten
times, the display will show “0.” (2 
3 3 
..... 
3 0 3 1 3 2 
... 
)
Receipt function status:
The indicator “_” appears in the RCPT OFF position when 
the receipt function is in the OFF status.
Time      : Appears in the far-right six positions (hour-minute - “ ” or 
hour-minute - “ ”) in the OP X/Z, REG, or MGR mode. “ ”
is displayed in the morning (AM), and “ ” in the afternoon 
(PM). In the REG or MGR mode, press the [#/TM/SBTL] key 
to display the time.
0 . 1 . 2 . 3 . 4 . 5 . 6 . 7 . 8 . 9 .
3 . 4 . 5 . 6 . 7 . 8 . 9 .
Operator display
Customer display 
(Pop-up type)
PLU/SUB
DEPT REPEAT
RCPT
OFF
NUMBER
SHIFT
DC
Clerk code
Page of 32
Display

Download Sharp XE-A113 (serv.man3) Service Manual (Repair Manual)

Here you can read online and download Sharp XE-A113 (serv.man3) Service Manual in PDF. XE-A113 (serv.man3) service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sharp XE-A113 (serv.man3) ECR. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.