3. Clock generator
The X1 generator 32.768KHz which is primarily used to update the
internal RTC (Real Time Clock).
The X2 generator 12MHz which is used as main clock.
4. P-OFF circuit
When the power is supplied, voltage Vo from the power supply circuit
rises. When it reaches about 6.2V, point A is driven to HIGH so that
the POF signal of the CPU is fixed to HIGH with Vcc and the CPU
performing power ON process.
When voltage Vo falls below about 6.2V by turning off the power,
point A is driven to LOW to fix the POF signal of the CPU to LOW and
the CPU performs power OFF process.
5. RESET circuit
Since Q1 is turned on by Vcc, the RES signal is driven to LOW to
reset the CPU. After that, discharging of C8 turns off Q1 to drive the
RES signal to HIGH.
6. Printer circuit
7. REWIND motor drive circuit
When the RWND signal from the CPU is HIGH, Q2 is turned on to
operate the motor.
8. DRAWER drive circuit
When the DR signal from the CPU  is HIGH, Q3 is turned on to
operate the solenoid.
XT1
XT2
X1
X2
CPU
IC1
X1
X2
32.768K
12M
C15
30p
C14
30p
C13
33 p
C12
22 p
POF
VO
VCC
ZD1
MTZ6.2B: XE-A110
MTZ6.2A: XE-A130
R4
5.6K
C7
3.3µF/50V
R6
100K
R5
56K
D5
A
from power supply circuit
VO
POF
VCC
VCC
VDD
RES
C8
22µF/50V
D6
R7
2.7K
R8
1K
R9
4.7K
Q1
C3198
C19
M104
TRG
Sub Timing puls detector
Timming puls detector
Reset puls detector
Driver
IC
T
VCC
M
t
R
Trrigger magnet
T
t
R
6V
V O
M
MOTOR
Q2
C3784
R11
15K
R10
1K
RWND
V O
R12
1 K
R13
15K
Q3
C3784
D R
Solenoide
– 7 –
Page of 16