XE-A101 (serv.man6). XEA101 Service Manual (Complete) - Sharp ECR Service Manual (repair manual). Page 10

Read Sharp XE-A101 (serv.man6) Service Manual online

5. PRINTER TEST
1) KEY OPERATION
2) TEST PROCEDURE
With the above key operation , the print test pattern is repeatedly
printed.
Pressing any key will terminate the test after the completion of one
cycle print. (The receipt is issued at the end.)
6. CPU VERSION NO. PRINT
1) KEY OPERATION
2) DESCRIPTION
The CPU version No. are printed with above key operation.
(Print example)
0101
CPU version NO.
06
This test is terminated when printing is completed.
7. BATTERY VOLTAGE SENSOR TEST
1) KEY OPERATION
2) TEST PROCEDURE
Displays A/D conversion port read value.
0155 or greater: Normal
0154 or smaller: Low battery display
0138 or smaller: No battery display and MSR is done when power on.
To terminate the test, press any key.
Completion print 
07
8. TIME DISPLAY TEST
1) KEY OPERATION
2) TEST PROCEDURE
To terminate the test and print the date and time, press any key.
9. DESTINATION DISPLAY
1) KEY OPERATION
2) TEST PROCEDURE
Display the destination code as follows.
V version
Display
1
Display
X   (X:1)
To terminate the test, press any key.
Completion print
09
PO
5
PO
6
PO
7
PO
8
8
Display 
Hour
Minute
Second 
Turn on and off(0.5s) 
7
5
4
2
1
3
6
Print 
Year Month Date    Hour Minute Second 
0  8
X X X X X X
X X X X X X
PO
9
Page of 25
Display

Click on the first or last page to see other XE-A101 (serv.man6) service manuals if exist.