UP-800 (serv.man26). UP-800, UP-810 Program Manual - Sharp ECR Service Manual (repair manual). Page 10

Read Sharp UP-800 (serv.man26) Service Manual online

UP-800F/810F (V)
SRV MODE PROGRAMMING (“SETTING”)
3 – 4
[01 DEVICE CONFIG] - [14 BCR (SCANNER)
* ER-A6HS1 setting : "BAUD RATE = 4800 bps" , "DATA BITS = 7Bits", "PARITY = ODD", "STOP BIT = 1Bit"
[01 DEVICE CONFIG] - [15 SCALE]
[01 DEVICE CONFIG] - [16 ONLINE]
[01 DEVICE CONFIG] - [17 POLE DISPLAY]
DISPLAY
CONTENTS
SELECT ITEM
MRS
NOTE
CHANNEL#
Channel No.
0-7
0
0:
 No RS232 channel is assigned.
1-7:  RS232 channel is assigned.
BAUD RATE
Transmission speed
4800 bps
4800 bps
9600 bps
19200 bps
DATA BITS
Data bit
7 Bits
7 Bits
8 Bits
PARITY
Parity bit
NON
ODD
EVEN
ODD
STOP BIT
Stop bit
2 Bits
1 Bit
1 Bit
DISPLAY
CONTENTS
SELECT ITEM
MRS
NOTE
CHANNEL#
Channel No.
0-7
0
0:
 No RS232 channel is assigned.
1-7:  RS232 channel is assigned.
DISPLAY
CONTENTS
SELECT ITEM
MRS
NOTE
CHANNEL#
Channel No.
0-7
0
0:  No RS232 channel is assigned.
1-7: RS232 channel is assigned.
DISPLAY
CONTENTS
SELECT ITEM
MRS
NOTE
WAITING TIME
Waiting time untilmessage is display-
yed on POLE.
0-3
0
3 digits (0 to 999 seconds) 
0 (No display)
Page of 62