UP-800 (serv.man26). UP-800, UP-810 Program Manual - Sharp ECR Service Manual (repair manual). Page 8

Read Sharp UP-800 (serv.man26) Service Manual online

UP-800F/810F (V)
SRV MODE PROGRAMMING (“SETTING”)
3 – 2
[01 DEVICE CONFIG] - [03 RECEIPT PRINTER]
* MRS default printer of UP-820 is BUILT-IN (820).
MRS default printer of UP-810 is BUILT-IN (810).
MRS default printer of other type is TM-T88 (3) /T88 (4).
[01 DEVICE CONFIG] - [04 SLIP PRINTER]
DISPLAY
CONTENTS
SELECT ITEM
MRS
NOTE
TERMINAL#
Terminal Number
0 - 254
0
0:
SELF TERMINAL No.
This means local device.
1 - 254: (EXCEPT SELF TERMINAL NO.)
This means re-routed device.
Re-routing programming  is only  valid for
printer.
CHANNEL#
Channel Number
0 - 7
0
"0" means no RS-232 channel is assigned.
PRINTER
Kind of printer
TM-T88 (3)/
T88 (4)
BUILT-IN
(820),
BUILT-IN
(810),
TM-T88 (3)/
T88 (4) 
*
About the usage of TM-T88 (3) :
•  It must be selected "TM-T88 (3) / 88 (4)" if it
dose not use the Graphic LOGO function.
• It must be selected "TM-88 (3) + LOGO" if it
uses the Graphic LOGO function.
TM-U220 / 230
Print format of TM-U210/220/230 is the same
as print format of TM-U210.
TM-T88 (3) (4)
+ LOGO
About the usage of TM-T88 (3) :
•  It must be selected "TM-T88 (3) / 88 (4)" if it
dose not use the Graphic LOGO function.
• It must be selected "TM-88 (3) + LOGO" if it
uses the Graphic LOGO function.
Print format of TM-T88 (3) is the same as print
format of TM-T88/85.
BUILT-IN (820)
BUILT-IN (810)
AUTO CUTTER
Auto cutter
YES
YES
NO
HEAD LOGO PRINT
Header LOGO print timing
 
PRE-PRINT
PRE-PRINT When a printer is not shared with another type
of printer, this selection should be done. 
This selection allows paper saving.
EACH ISSUE
When a printer is shared with another type of
printer, this selection should be done. 
This selection does not allow saving paper. 
But, RECEIPT LOGO will not be printed on
another type of printer.
RCPT LENGTH
Minimum length for BILL on receipt
0 - 30 Lines
0
2 digits
DISPLAY
CONTENTS
SELECT ITEM
MRS
NOTE
TERMINAL#
Terminal No.
000 - 254
000
000 : 
Self terminal No.
This means local device.
1-254:  Except self terminal No.
This means re-routed device.
Re-routing programming is only valid for printer.
CHANNEL#
Channel No.
0 - 7
0
0:  No RS232 channel is assigned.
1-7: RS232 channel is assigned.
PRINTER
Kind of printer 
TM-U295
EPSON 
TM-295
TM-T88 (3) /
T88 (4)
TM-T88 (3) /
T88 (4)+LOGO
TM-U220/U230
INITIAL FEED#
Initial SLIP feed line number
00 - 64
00
SLIP MAX LINE
Slip print maximum line No.
00 - 99
99
VP PRINT TIMES
No. of times of validation print
0 - 9
1
Page of 62
Display