- 9 -
Initial scale display:
                                                                                                                       
0.000
0.00
       0.00                                   
      kg            EUR/kg      
EUR
Scale timer set to “0” sec (scale item data only are displayed):
  
Department- / PLU- Text                                                                            
1.000    
1.00
       1.00
      kg            EUR/kg             EUR
Scale timer set to other value than “0” sec (none-scale item data also displayed):
  
Department- / PLU- / EAN- / Function Text                                                                           
           
0.000
0.00
       1.00                                                   
                                    kg              EUR/kg           EUR
10.  
“AUTO” key setting in “Function Menu”
It is now possible to set “Auto” keys into Function menus, which allows for example to make a auto
key sequence for PLU registration which has a information text without operation of the “CANCEL”
key before PLU registration can be done.
11. EAN 
learning 
function
Registered EAN codes by the “Learning Function” are not stored in the PLU / EAN file for Charity
shop application in the UK.
SRV#929-C setting:
Storage in the PLU / EAN file  “No/Yes”(+4/0).
Default value is set to “Yes”.
12.
 Free text function
The Free text qty “1x” print can be cut from receipt print in order to allow reason code entry for
“Return goods”.
SRV#929-C setting:
“1x” qty is cut on receipt “Yes/No” (+2/0).
Default value is set to “No”.
13. 
Kitchen printer function
The “Attempt Retry” pop-up window is re-introduced in case of KP failure and KP spare printer
definition.
SRV#929-B setting:
Pop-up window “Yes /No”(+4/0).
Default value is set to “No”.