UP-800 (serv.man21). UP-800 Series Enhancement ROM (V1.6x) Program Operation Manual (This manual contains details on the enhanced features including some Orderman enhancements) - Sharp ECR Service Manual (repair manual). Page 3

Read Sharp UP-800 (serv.man21) Service Manual online

Page 3 - 13
1.
 
General
The ROM version V1.60 is not compatible (neither Data nor Language Text Resources) with the previous ROM
version V1.52. For details refer from chapter 19 onwards.
2.
 
All Clerk CCD function.
All Clerk CCD function has been added at this version. By setting SRV #988D to 4, the CCD function for All Clerk is
activated. No further reports can be taken unless the All Clerk Z report has been issued.
1. CCD compulsory
988-D
Default
Non-compulsory
0
For INDIVIDUAL CLERK (CASHIER)
1
For TERMINAL CCD
2
For CCD PER SHIFT
3
For ALL CLERK
4
3.
 
CCD information at Terminal CCD report.
At Inline System, the information for CASH IS, CCD DIFF. and DIF. TL from the
Satellite are not printed on the consolidated General System Z report. This has been
corrected and these totalizers are printed as well.
4.
 
Clerk Real Key at the ECR with an Orderman system.
Now it is possible to process Orderman registrations, even a Clerk Real Key is assigned at ECR.
In case a normal transaction has been started, this transaction will be placed in the background.
After the Orderman registration has been processed, the former registration will be recalled.
GLU registrations will be finalized with NBAL.
The start of such an action is defined by the setting of the Orderman Clear Timer.
5.
 
“Bar machine without KP print” function (special function for Orderman)
By introducing a new Service Parameter #903D (not used in previous versions) it is possible to set a KP number (1 to
9) to realise a so called “Bar machine without KP print” function.
Relevant item registrations (KP# X assigned) done at a terminal which has the KP# X set at SRV#903D=X are not
printed at this defined KP. Items booked at the Orderman or any other terminals (SRV#903-D=0) are printed as usual
at this Kitchen printer.
1. Kitchen Printer #
903-D
Default
KP assigned item registration are printed at all KP’s
0
KP assigned item registrations from this terminal are not printed at the
set KP#.
1~9
Page of 13