ER-A610 (serv.man23). Paper End Sensor, Scanning Problem - Sharp ECR Technical Bulletin (repair manual). Page 2

Read Sharp ER-A610 (serv.man23) Technical Bulletin online

2/5
4. Action:
((For the field))
  Either of the following two countermeasures should be taken against the above 3-1).
  1) The following should be set in case  a code beginning with 200 in an EAN 8 CODE is not
treated as a PLU.
Key sequence
  PGM2 MODE
             2616 [ 
• 
] [ X ] 13 [ X ] 
∗∗
0001
∗∗
 [ ST ]  [ TL ]
                  
 Input your selected data.
                    (Refer to page 46 in the PROGRAMMING MANUAL for ER-A610.)
  2) The following SSP should be issued in case a code beginning with 200 in an EAN 8
CODE is treated as a PLU.
SSPERA610-002   Model applicable:  ER-A610
(ROM VERSION NO. RAI1A & RAI1B)
Note) ER-A570, without this function, requires no countermeasure.
  The following SSP should be issued against the above 3-2).
SSPERA610-003   Model applicable:  ER-A610
(ROM VERSION NO. RAI1A & RAI1B)
SSPERA570-003   Model applicable:  ER-A570
(ROM VERSION NO. RAJ1A & RAJ1B)
((For production))
  Simultaneous correction will be carried out when a ROM VERSION change is required.
5. Remarks:
 Special Service Preset Setting Data and order
                             SSPERA610-002
                             SSPERA610-003
                             SSPERA570-003
Page of 5