3. File creation terminates successfully and a request for floppy
disk replacement is made.
PRINT FORMAT
#0896 ∗Π Γ Μ ≤ ∗
JOB CODE/MODE TITLE
 
σενδ
 
              ερρορ 8
φ1200111. δατ       οκ
DISPLAY FORMAT
  F1200111     OK?
The TL key can be entered.
4. After the existing floppy disk, the CA key is entered.
Then the remaining data is successfully stored in another file
in the new disk.
PRINT FORMAT
 
#0896 ∗Π Γ Μ ≤ ∗ 
JOB CODE/MODE TITLE
 
σενδ 
 
              ερρορ 8 
φ1200111. δατ       οκ 
φ1200111. δατ       οκ 
 
DISPLAY FORMAT
 
SEND     F1201111
Note 1: The table file (file No. 700) cannot extend over multi-
ple media (floppy disks).
Note 2: If the floppy disk contains any file that is the same in
file name as the file to be created in a file creation
step 2 or 4 above, "FILE NAME SEND?" appears on
the ECR display.
To create the file, it is necessary to enter the TL key;
and otherwise it is necessary to enter the  
 key.
Those file extending over multiple media (floppy disks) can
be received by performing the ordinary receive operation
(see 4-6)).
4-6) Receiving file data from the ER-02FD
This function causes the ECR to receive file data from the ER-02FD.
Procedure for PGM job #898
The ECR can receive specified files from a floppy disk in the ER-
02FD connected to it when the above job is performed.
If any specified file is not present in the ECR, a "ENTRY ERROR"
error occurs.
PRINT FORMAT
When the send operation has successfully terminated:
#0895 ∗Π Γ Μ ≤ ∗
JOB CODE/MODE TITLE
 
ρεχει ϖε
 
φ1100111. δατ       οκ
When the send operation has been canceled:
#0898 ∗Π Γ Μ ≤ ∗ 
 
ρεχει ϖε 
 
φ1100111. δατ   ερρορ4 
ERROR4
(Specified file is not present.)
DISPLAY FORMAT
During a Receive operation
RECEIVE F1100111
If ECR memory space is full when ECR is receiving the data, a
"MEMORY FULL" error occurs. (The data received before the
"MEMORY FULL" error occurs is valid.)
PRINT FORMAT
When "MEMORY FULL" error occurs:
 
#0895 ∗Π Γ Μ ≤ ∗
JOB CODE/MODE TITLE
 
ρεχει ϖε
 
φ010ξξξξ. δατ       οκ
 
µεµορψ φυλλ
4-7) Presetting and reading of stack files
The presetting of stack files enables those files to be loaded and
dumped with a single job.
This presetting is of addition type. The following two kinds of preset-
ting are available.
Stack file presetting 1
PGM2 MODE
Stack file presetting 2
PGM2 MODE
PRINT FORMAT
When "MEMORY FULL" error occurs:
 
#0887 ∗Π Γ Μ ≤ ∗ 
JOB CODE/MODE TITLE
 
         φ1101111. δατ 
Stack file preset
         φ1201111. δατ 
         φ1301111. δατ 
φ1401111. δατ     −−−− 
Individual deletion of stack file
(FILE No.)
TL
898
X
(FILE No.)
ST
887
X
TL
X
TL
For individual deletion
atack files
For full deletion of atack files
(Up to 20 files can be preset)
(FILE No.)
ST
888
X
TL
X
TL
For individual deletion
atack files
For full deletion of atack files
(Up to 20 files can be preset)
 51 
Page of 54
Display