4. Service mode programming
The following are the key operation required for programming.
Details of [A][B][C][D] will be discussed at each item description.
 mark is MRS setting.
[JOB #901]:MRS=0102
#901-A: Not used (Fixed at "0")
#901-B: Tax system
1. TAX system
901-B
Auto TAX 1~6
0
Auto VAT 1~6
1
Manual VAT 1~6
2
Manual VAT 1
3
Manual TAX 1~6
4
Auto VAT 1~3 and Auto TAX 4~6
5
#901-C: 1. Rounding system
1. Rounding system
901-C
Normal
0
SWEDEN
1
DENMARK
4
#901-D: 1. TAB setting
1. TAB setting
901-D
0
.
     
0
0.0  
1
0.00 2
0.000
3
[JOB#902] MRS=0000
#902-A, B, C: Not used (Fixed at "000")
#902-D: 1. EFT function
1. EFT function
902-D
No
0
Yes
4
[JOB#903] MRS=4000
#903-A:
1. IR communication baud rate
1. Baud rate (bps)
903-A
 2400
2
 4800
3
 9600
4
19200
5
38400
6
57600
7
115200 8
*
The communication speed with the ER-02FD is 19200
bps.
#903-B, C, D: Not used (Fixed at "000")
[JOB#904] MRS=0000
#904-A: 1. Printing of date
1. Printing of date
904-A
Yes
0
No
4
#904-B: 1. Printing of consecutive No.
1. Printing of consecutive No.
904-B
Yes
0
No
4
#904-C: 1. Service charge is contained in ST.
1. Service charge is contained in ST
904-C
No
0
Yes
4
#904-D: 1. Inclusion of tax in base amount of service charge.
  1. Inclusion of tax in base amount of 
 service 
charge
904-D
No
0
Yes
4
[JOB#905] MRS=0100
#905-A: Not used (Fixed at "0")
#905-B: 1. Tax printing when taxable subtotal is zero.
2. Tax printing when tax is zero.
1. Taxable subtotal is
zero
2. Tax is zero
905-B
Skip
Print
0
Skip
1
Print
Print
4
Skip
5
#905-C: 1. Printing of rounding amount in receipt. (For Australia)
2. Printing format for split pricing entry.
1. Printing of rounding
amount in receipt
2. Printing format for split
pricing entry
905-C
No
Normal format
0
Australia format
1
Yes
Normal format
2
Australia format
3
#905-D : Not used (Fixed at "0")
[JOB#906] MRS=0001
#906-A:
1. Print Dept. and PLU number on receipt.
2. Entry which makes the PLU stock counter negative
1. Print Dept. and PLU
number on receipt.
2. Entry which makes
the PLU stock
counter negative
906-A
No
Allowed unconditionally
0
Operation allowed
despite ERROR
message
1
Inhibited
2
Yes
Allowed unconditionally
4
Operation allowed
despite ERROR
message
5
Inhibited
6
XXX
TL
(Job#)
[A] [B] [C] [D]
Numeric entry
4 digits max
0
– 6 –
Page of 56