ER-A490 (serv.man3). ERA490 Programming Manual - Sharp ECR Service Manual (repair manual). Page 47

Read Sharp ER-A490 (serv.man3) Service Manual online

[JOB#2619]
HOURLY REPORT (Starting time)
a:
 Memory format
A
 30 minutes (24 hour)
0
 15 minutes (12 hour)
1
bb:
Starting time (hour):
00 
 23
ex)
 Case 1.
X1 Hourly report (#160) (15 min, start time = 7]
#160 
   7:00
     (data)
   7:15
     (data)
   7:30
  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
12 hour started from 7:00
     (data)
   7:45
     (data)
 subtotal
     (data)
          |
          |
  18:45
     (data)
 subtotal
     (data)
   **:**
     (data)
Data out of range (19:00 to 6:59)
[JOB#2620]
STACK REPORT
XX:
 JOB#
SSSSSS:
 Start code
EEEEEE:
 End code
JOB#
REPORT NAME
TYPE
00
General
10
DEPT./GROUP
13
DEPT. All group
20
PLU
RANGE
23
PLU group total
24
PLU stock
RANGE
27
PLU zero sales
29
PLU price category
RANGE
30
Transaction
31
CID
32
Commission sale
50
All cashier
60
Hourly
RANGE (only X report)
70
Daily net
80
GLU
RANG
82
Balance
[
**
]
Max. 70 step are programmable. "1 step" means the memory size
used for one no range type JOB#.
The RANGE type JOB# means "8 steps".
For example)
The memory size for programming JOB#00, 20 and 50 is 10 steps.
(ie. 1 step for JOB#00, 8 step for JOB#20, and 1 step for JOB#50. )
[JOB#2630, 2631, 2632]
SECRET CODE PROGRAMMING
#2630:  PGM1 mode
#2631:  X1/Z1 mode
#2632:  X2/Z2 mode
*
If "0" is entered, "compulsory secret code entry" is canceled.
MRS = 0
2619
abb
0
TL
2619
107
TL
2620
XX
SSSSSS
EEEEEE
All delete
No range
Next JOB# (max.=16)
ST
TL
2630,2631,2632
XXYY
0
TL
– 45 –
Page of 56