ER-A440 (serv.man5). ERA440 Programming Manual - Sharp ECR Service Manual (repair manual). Page 40

Read Sharp ER-A440 (serv.man5) Service Manual online

CHAPTER 3. OP X/Z, X1/Z1,X2/Z2
MODE
The following categories of reports can be printed by the ECR.
1) OP X/Z reports (individual clerk reports)
2) X1/Z1 reports (Daily sales total X and Z reports)
3) X2/Z2 reports (Periodic total X and Z reports)
To print reports, use the following key entry sequence
JOB#
Range is required
Reading
Resetting
TL
MODE  1
OP X/Z
X1/Z1
X2/Z2
F-read
3 DATA FOR 
REPORT NAME
X
Z
X1
Z1
X2
Z2
X1  4
JOB#
READING
NOTE
GENERAL
00
DEPT/GROUP
10
IND. GROUP
12
GROUP No.
GROUP TOTAL
13
PLU BY RANGE
20
PLU CODE
2
PLU BY DEPT
21
DPT CODE
PLU ZERO SALES
27
ALL
PLU PRICE CATEGORY
29
PRICE
2
TRANSACTION
30
TL-ID
31
COMMISSION SALES
32
ALL CLERK
40
IND. CLERK
41
ALL CASHIER
50
IND. CASHIER
51
HOURLY (ALL)
60
HOURLY 
(RANGE)
60
TIME
2
DAILY NET
70
STACKED REPORT
90
1 X1:  Daily X report
Z1:  Daily Z report
X2:  Periodic X report
Z2:  Periodic Z report
Stop of printing reports:
The printing of all reports can be stopped by the following operation.
Set the mode switch to "MGR" to cancel.
Note) When the printing is stopped, the consecutive number or Z
counter don’t return to the original value.
When Z reports, Memory is not reset.
1 X1: Daily X report
X2: Periodic X report
Z1: Daily Z report
Z2: Periodic Z report
2 PLU code range can be specified by entering the start and end
numbers according to the following procedure. When specifying
a single time interval, PLU code, the start number has only to be
entered.
3 When 2 is entered in the third digit of a job code, periodic reports
are printed.
Example: Daily general report;  job code 100
Periodic general report;  job code 200
4 Reading display only
    KEY    
→  
 CL 
 (Display 
amount) (Display 
initialize)
 KEY 
DEPT
= DEPTn key
CID
 key
Daily Net = ST key
An individual report is printed on the receipt and journal when the
TL key is pressed.
Pressing the decimal point key just after the entry of a job code
clears the corresponding data in the ECR. (Z report)
(When printing those reports for which no Z reports can be taken,
the decimal point key cannot be pressed after the entry of a job
code.)
When the decimal point key is not pressed after the entry of a job
code, the corresponding data is held in the ECR. (X report)
XXXXXX
XXXXXX
All
Start No.
End No.
3 – 1
Page of 42