ER-A440 (serv.man5). ERA440 Programming Manual - Sharp ECR Service Manual (repair manual). Page 36

Read Sharp ER-A440 (serv.man5) Service Manual online

5) PLU PRESET PRICE SETTING
Mode: PGM1/PGM2
XXXXXX: PLU CODE (1 to 999999)
YYYYYY: UNIT PRICE (6 digits)
If the record of entered PLU code is not in PLU file at this program-
ming, it will be created in PLU file.
MRS = 0
If the [PLU] or [PLUn] key is depressed, programming mode is
changed from "PRICE PROGRAMMING" to "ATTRIBUTE PRO-
GRAMMING" and changed to "PLU ASSOCIATION PROGRAM-
MING" by depressing the same key again.
(Caution!!)
The associated department is changed if the operater depress
[DPTn] key instead of [PLUn] key by mis-operation at this timing.
6) PLU ASSOCIATION TO DEPARTMENTS
Mode: PGM1/PGM2
XXXXXX:
PLU CODE (1 to 999999)
YY:
Dept. code (1 to 50)
If the record of entered PLU code is not in PLU file at this program-
ming, it will be created in PLU file.
MRS = 01
If the [PLU] or [PLUn] key is depressed, programming mode is
changed from "PRICE PROGRAMMING" to "ATTRIBUTE PRO-
GRAMMING" and changed to "PLU ASSOCIATION PROGRAM-
MING" by depressing the same key again.
(Caution!!)
The associated department is changed if the operater depress
[DPTn] key instead of [PLUn] key by mis-operation at this timing.
Triple depression of [PLU] or [PLUn] key is necessary for the
first time.
7) PROGRAMMING OF PLU/SUBDEPT
Mode: PGM2
XXXXXX:
PLU CODE (1 to 999999)
A:
Sign
A
+
0
1
B:
Taxable6
B
Non taxable
0
Taxable
1
C:
Taxable5
C
Non taxable
0
Taxable
1
D:
Taxable4
D
Non taxable
0
Taxable
1
E:
Taxable3
E
Non taxable
0
Taxable
1
F:
Taxable2
F
Non taxable
0
Taxable
1
G:
Taxable1
G
Non taxable
0
Taxable
1
H:
Amount entry type
H
Inhibited
0
Open
1
Preset
2
Open and preset
3
Delete
4
If the record of entered PLU code is not in PLU file at this program-
ming, it will be created in PLU file.
MRS = 00000002
If the [PLU] or [PLUn] key is depressed, programming mode is
changed from "PRICE PROGRAMMING" to "ATTRIBUTE PRO-
GRAMMING" and changed to "PLU ASSOCIATION PROGRAM-
MING" by depressing the same key again.
(Causion!!) The associated department is changed if the oper-
ater depress [DPTn] key instead of [PLUn] key by
mis-operation at this timing.
Double depression of [PLU] or [PLUn] key is necessary for the
first time.
8) PROGRAMMING RATE FOR %KEY.
Mode: PGM1/PGM2
XXX.XX:
0.00 to 100.00
MRS = 0.00%
If the same [%n] key is depressed, programming mode is changed
from "RATE PROGRAMMING" to "FUNCTION PROGRAMMING"
(from "FUNCTION PROGRAMMING" to "PRICE PROGRAM-
MING").
Not changed
XXXXXX
PLU code
for next code
YYYYYY
PLU
PLUn
ST
TL
XXXXXX
PLU code
PLU delete
PLU
PLUn
for next code
DPTn
VOID
YY
Not changed
ST
TL
Not changed
XXXXXX
PLU code
for next code
ABCDEFGH
PLU
PLUn
TL
Not changed
%n
XXX.XX
TL
ST
*
2 – 21
Page of 42
Display