ER-A410, ER-A420 SCANNING (serv.man3). ERA410 420 Dealer Manual for Scanning Roms - Sharp ECR Service Manual (repair manual). Page 14

Read Sharp ER-A410 / ER-A420 SCANNING (serv.man3) Service Manual online

                                                               
System Presets
 
Designs and specification are subject to change without notice                                                                                        Page 14 
 
System Preset: 905 
Bit 
Description 
Data 
MRS 
Defaults  
 
 
 
A410  A420 
Tax4 Subtotal is printed on Trans. Reports  
No/Yes 
 4/0 
Gross Tax4 & Refund Tax4 Totals are printed on Trans. 
Reports 
No/Yes 2/0 
Net Tax4 Total is printed on Trans. Reports 
No/Yes 
1/0 
Enter SUM of Selection ----^ 
 
0 0 
Tax is printed when the Taxable Subtotal = $0.00 
Yes/No 
4/0 
Tax is printed when GST is VAT 
No/Yes 
2/0 
Tax is printed when Tax = $0.00 
No/Yes 
1/0 
Enter SUM of Selection ----^ 
 
0 0 
GST Exempt is printed on Trans. Reports 
No/Yes 
4/0 
---- --- 
---- ---- 
Enter SUM of Selection ----^ 
 
0 0 
Canadian Tax System: 
Type10/Type9/Type8/Type7/Type6/Type5/Type4/Type3/Type2/Type1 
9/8/7/
6/5/4/
3/2/1/
Enter SUM of Selection ----^ 
 
5 5 
NOTE: 
•  905-C is related to 905-D the Canadian Tax System 
System Preset: 906 
 
Bit 
Description 
Data 
MRS 
Defaults 
 
 
 
A410 
A420 
Dept. & PLU/UPC Codes are printed 
Yes/No 
4/0 
A  PLU/UPC (EAN) Stock System: 
Entry is Inhibited/Error Message and Operation continues/Allowed 
2/1/0 
Enter SUM of Selection ----^ 
 
0 0 
Bottle Return Function is Enabled 
Yes/No 
4/0 
Hash Dept. is Enabled 
Yes/No 
2/0 
---- 
--- 
Enter SUM of Selection ----^ 
 
0 0 
Multiplication System: 
Fast Food (FF sequence)/Split-Price/Successive 
Multiplication/Multiplication 
 
3/2/1/
Enter SUM of Selection ----^ 
 
2 2 
PLU/UPC (EAN) Price Look Up at Refund Entry 
No/Yes 
4/0 
Presetting of the Consecutive No. is Enabled 
No/Yes 
2/0 
Fractional Qty System is enabled (3 decimal places) 
Yes/No 
1/0 
Enter SUM of Selection ----^ 
 
0 0 
NOTE: 
•  906-D must not be changed until after totalizers are reset (Qty 0 Æ 0.000 & vice-versus) 
•  Fractional entries are disabled when a SCALE is enabled in PGM2 Job #2690 programming. 
Page of 127
Display