ER-A310 (serv.man2). ERA310 330 Service Manual - Sharp ECR Service Manual (repair manual). Page 18

Read Sharp ER-A310 (serv.man2) Service Manual online

2
Description
Until the depression of the  
ST key, the sum of key position
codes is compared with the sum check data, except for the
 TL/NS  key.
3
Termination
The test terminates with the depression of the  TL/NS  key and
the termination printout is produced.
Termination print at normal end
******
 0 2
Termination print at error
*******
 2
4)  Test No. 4: Display and buzzer test
1
Key operation
2
Description
Continuous beeps and the display are tested.
1. 2. 3. 4. 5. 6. 7. 8. 9. 0.
  State of display
The decimal point is shifted digit by digit from the lowest digit
(every 200 msec).
Then all segments are lighted (for about 1 sec).
8. 8. 8. 8. 8. 8. 8. 8. 8. 8.
  State of display
Pressing any key will terminate the test.
3
Check items
Check that each position display is correct.
Check that the display is even and uniform.
Check that the buzzer sound is normal. (No interruption and vibra-
tions of sounds.)
4
Test end
End 
print
      3
5)  Test No. 5, 6: Drawer open test
1
Key operation
2
Description
With this test, the drawer opens and its state is displayed in the
following manner:
Drawer open
 XX                    0 
Drawer closed
 XX                    C   
XX = 04 or 14
*
When the model that has no drawer sensor switch, displayed is
"C".
3
Termination
With depression of any key
Termination print
04 (For standard drawer)
14 (For Option drawer)
6)  Test No. 7: Continuous print test
1
Key operation
2
Description
The continuous printing as shown below is performed.
67
56
35
75
05
25
70
10
00
41
21
11
31
20
01
04
63
34
74
13
54
43
23
03
53
33
73
68
55
45
76
15
26
65
78
38
37
27
08
77
48
47
61
R
J
66
42
32
72
02
28
18
3
ST
4
14
: For stardard drawer
: For option drawer
ST
ST
5
ST
– 17 –
Page of 23
Display