ER-A280, ER-A280N, ER-A280F (serv.man4). ER-A280 Programming Manual - Sharp ECR Service Manual (repair manual). Page 7

Read Sharp ER-A280 / ER-A280N / ER-A280F (serv.man4) Service Manual online

ER-A280F/280N (V)
SRV MODE PROGRAMMING
2 – 2
3. SYSTEM PRESET
[JOB#901] : MRS = 0102 (ER-A280F/N)
0112 (Sweden fiscal)
901-A: 1 EFT easy card
901-B: 1 Tax system (Sweden fiscal is fixed)
901-C: 1 Rounding system
901-D: 1 TAB setting (Sweden fiscal is fixed)
[JOB#902] : MRS = 0000
902-A, B: Not used (Fixed at "00")
902-C: 1 Clerk report format
902-D: 1 EFT terminal
[JOB#903] : MRS = 0000
903-A, B, C, D: Not used (Fixed at “0000”)
[JOB#904] : MRS = 0000
904-A: 1 Printing of date (Sweden fiscal is fixed)
904-B: 1 Printing of the consecutive No. (Sweden fiscal is fixed)
904-C, D:Not used (Fixed at “00”)
[JOB#905] : MRS = 0100
905-A: Not used (Fixed at “0”)
905-B: 1 Tax printing when taxable subtotal is zero.
2 Tax printing when tax is zero.
905-C: 1. Printing of rounding amount in receipt. (For Australia)
2. Printing format for split pricing entry. (For Australia).
905-D : Not used (Fixed at “0”)
[JOB#906] : MRS = 0001 (ER-A280F/N)
0002 (Sweden fiscal)
906-A: 1 Printing of PLU code (DEPT code is never printed.)
2 Entry which makes the PLU/EAN stock counter negative
1
901-A
280F/N
Sweden
No
0
Yes
2
1
901-B
280F/N
Sweden
Auto TAX 1 - 6 
0
Auto VAT 1 - 6
1
Manual VAT 1 - 6 
2
Manual VAT 1
3
Manual TAX 1 - 6
4
Auto VAT 1 - 3 and Auto TAX 4 - 6
5
1
901-C
280F/N
Sweden
Normal
0
SWEDEN
1
DENMARK
4
1
901-A
280F/N
Sweden
0.0 1
0.00
2
0.000
3
1
902-C
280F/N
Sweden
Type 1 : Clerk only for Hospitality
0
Type 2 : Clerk only for Retail
1
Type 3 : Cashier + Clerk for Retail
2
1
902-D
280F/N
Sweden
No
0
Yes
4
1
904-A
280F/N Sweden
Yes
0
No
4
1
904-B
280F/N Sweden
Yes
0
No
4
1
2
905-A
280F/N Sweden
Skip
Print
0
Skip
1
Print
Print
4
Skip
5
1
2
905-C
280F/N Sweden
No
Normal format
0
Australia format
1
Yes
Normal format
2
Australia format
3
1
2
906-A
280F/N Sweden
No
Allowed 
unconditionally
0
Operation allowed 
despite error mes-
sage
1
Inhibited
2
Yes
Allowed 
unconditionally
4
Operation allowed 
despite error mes-
sage
5
Inhibited
6
Page of 49
Display

Click on the first or last page to see other ER-A280 / ER-A280N / ER-A280F (serv.man4) service manuals if exist.