ER-A280, ER-A280N, ER-A280F (serv.man4). ER-A280 Programming Manual - Sharp ECR Service Manual (repair manual). Page 11

Read Sharp ER-A280 / ER-A280N / ER-A280F (serv.man4) Service Manual online

ER-A280F/280N (V)
SRV MODE PROGRAMMING
2 – 6
914-C: 1 Void mode (Sweden fiscal is fixed)
914-D: 1 Check cashing (Sweden fiscal is fixed)
[JOB#915] : MRS =0060
915-A, B: Not used (Fixed at “00”)
915-C: 1 No. of times of st(-) or st(%) entry within one transaction
915-D: Not used (Fixed at “0”)
[JOB#916] : MRS = 1000
916-A: 1 Action to be taken when text and amount overlaps each other
in a REG-mode entry 
916-B: 1 Finalization by charge/credit when ST t  0
2 Tendering which is smaller than the sales amount 
916-C: 1 Negative merchandise subtotal
2 Subtotal entry before tender
3 Subtotal entry before direct non-tendering finalization
916-D: 1 Coupon PLU printing on X/Z report
2 Net sales subtotal (NET1) printing on X/Z report (Sweden fis-
cal is fixed)
3 Check change total printing on X/Z report
[JOB#917] NOT USED : MRS =0000
[JOB#918] : MRS = 0000
918-A: 1 Printing of text for associated PLU in set PLU.
2 Direct non-tendering finalization after previous tender en-try.
918-B: Not used (Fixed at “0”)
918-C: 1 Printing of Z1/Z2 counter in Z reports (Sweden fiscal is fixed)
918-D: Not used (Fixed at “0”)
[JOB#919] : MRS = 4000
919-A: Not used (Fixed at "4")
919-B: 1 Checking of clerk# on GLU reorder is made
2 Guest check number
919-C: 1 GLU entry
2 Amount printing when PLU unit price is zero
1
914-C
280F/N
Sweden
Enable
0
Disable
2
1
914-C
280F/N
Sweden
Enable
0
Disable
2
1
915-C
280F/N
Sweden
Any No. of times
4
Only once
6
1
916-A
280F/N
Sweden
Eat in
0
2 line print
1
1
2
916-B
280F/N
Sweden
Inhibit
Enable
0
Disable
2
Allowed
Enable
4
Disable
6
1
2
3
916-C
280F/N
Sweden
Enable
Non-
compulsory
Non-
compulsory
0
Compulsory
1
Compulsory
Non-
compulsory
2
Compulsory
3
Disable
Non-
compulsory
Non-
compulsory
4
Compulsory
5
Compulsory
Non-
compulsory
6
Compulsory
7
1
2
3
916-D
280F/N
Sweden
Print
Print
Print
0
Skip
1
Skip
Print
2
Skip
3
Skip
Print
Print
4
Skip
5
Skip
Print
6
Skip
7
1
2
918-A
280F/N Sweden
Print
Disable
0
Enable
2
No
Disable
4
Enable
6
1
918-C
280F/N Sweden
Yes
0
No
4
1
2
919-B
280F/N Sweden
Yes
Auto 
generation
0
Manual
1
No
Auto 
generation
4
Manual
5
1
2
919-C
280F/N Sweden
Non-
compulsory
No
0
Yes
1
Compulsory
No
2
Yes
3
Page of 49
Display

Click on the first or last page to see other ER-A280 / ER-A280N / ER-A280F (serv.man4) service manuals if exist.