XL-HP600 (serv.man21) - Sharp Audio Service Manual (repair manual). Page 14

Read Sharp XL-HP600 (serv.man21) Service Manual online

XL-HP600E
– 14 –
Standard Specification of Stereo System Error Message Display Contents
                     Error Contents
DISPLAY
                               Notes
CD
Pickup Mechanism Error.
'ER-CD**'
01: PU-IN SW Detection NG.
CD Changer Mechanism Error.
'ER-CD**'
10: Changer Error.
 (*)
11: Initial Error.
CD DSP Communication Error
'ER-CD**'
31: DSP COMMUNICATION ERROR
Focus Not Match.
'NO DISC'
TUN
PLL Unlock.
 
FM 
  
87.50
 
  MHz
PLL Unlock.
(*) CHECKING:
If CD changer mechanism error is detected, 'CHECKING' will be display instead of 'ER-CD**' display 'ER-CD**' will only be display
when CD changer mechanism error had been detected for the 5 th times.
Speaker abnormal detection and +B PROTECTION display
In case speaker abnormal detection or +B PROTECTION had occurred, it can be check by pressing 'POWER', 'VIDEO' and 'X-
BASS' key twice. Display will show "S** B**". S is referring to speaker abnormal detection and B is referring to +B PROTECTION.
** is in hex valve.
+B PROTECTION is condition when irregular process occur on power supply line.
Before transporting the unit
The following process need to be taken after set tapering/parts replacement.
1.  Press the ON/STAND-BY button to enter stand-by mode.
2.  While pressing down the 
 button and the X-BASS/DEMO button, press the ON/STAND-BY button until "CLEAR AL"appears.
3.  While pressing down the 
 / 
 button and the X-BASS/DEMO button, press the ON/STAND-BY button until "WAIT 
     FINISHED" appears.
4.  Unplug the AC cord and the unit is ready for transporting.
Page of 64
Display

Click on the first or last page to see other XL-HP600 (serv.man21) service manuals if exist.