XL-HP600 (serv.man21) - Sharp Audio Service Manual (repair manual). Page 12

Read Sharp XL-HP600 (serv.man21) Service Manual online

XL-HP600E
– 12 –
CD ERROR CODE DESCRIPTION
Error
Explanation
01
When Pickup set inner position, inner switch
cannot detect 'ON' level for 10 secs.
10*
Cam error. Can't detect cam switch when cam is
moving.
11*
When it detect cam operation error during initialize
process.
20
Tray error. Can't detect tray switch when tray is
moving.
21
When it detect tray operation error during initialize
process.
31
When it change to CD function, DSP cannot read
initial data.
Test Stage
Frequency
Frequency
Display
Setting/
Adjusting
Parts
Instrument
Connection
CD SECTION
•••••     
 AM IF/RF
Signal generator: 400 Hz, 30%, AM modulated
*1. Input: Antenna
Output: TP302
*2. Input: Antenna
Output: TP301
TUNER SECTION
fL: Low-range frequency
fH: High-range frequency
AM IF
450 kHz
1,620 kHz
T351
*1
AM Band
522 kHz
(fL): T306
*2
Coverage
1.1 
±
 0.1 V
AM Tracking 990 kHz
990 kHz
(fL): T303
*1
Figure 12-2 ADJUSTMENT POINTS
Items adjusted automatically
(1) Offset adjustment (The offset voltage between the head
amplifier output and the VREF reference voltage is
compensated inside the IC.)
  * Focus offset adjustment
  * Tracking offset adjustment
(2) Tracking balance adjustment
(3) Gain adjustment (The gain is compensated inside the IC
so that the loop gain at the gain crossover frequency will
be 0 dB.)
  * Focus gain adjustment
  * Tracking gain adjustment
  Adjustment
Since this CD system incorporates the following automatic
adjustment functions, readjustment is not needed when
replacing the pickup. Therefore, different PWBs and pickups
can be combined freely.
Each time a disc is changed, these adjustments are
performed automatically. Therefore, playback of each disc
can be performed under optimum conditions.
* 'CHECKING'
If Error is detected, 'CHECKING' will be displayed instead of
'ER-CD**'. 'ER-CD**' display will only be displayed when error
had been detected for the 5th times.
•  FM IF
Notes:
1. Description of the "FM IF Adjustment" is not carried on this
Manual. It is because the IF coil in the FM front end section
has been best adjusted in the factory so that its further
adjustment is not needed at the field. When replacing the
FM front end assembly, no adjustment is needed either.
2. The parts in the FM front end section are prepared in a
complete unit, so you can't obtain each part individually.
ADJUSTMENT
MECHANISM SECTION
•••••
 Driving Force Check
Torque Meter
Specified Value
Play: TW-2111
Over 80 g
 Torque Check
Torque Meter
Play: TW-2111
30 to 80 g.cm
Fast forward: TW-2231
70 to 180 g.cm
Rewind: TW-2231
70 to 180 g.cm
Specified Value
Specified
Value
Adjusting
Point
Instrument
Connection
Test Tape
Normal
MTT-111
Variable
3,000 
±
 30 Hz
Speaker
speed
Resistor in
Terminal
motor.
(Load
resistance:
6 ohms)
•••••
 Tape Speed
Figure 12-1
TAPE MECHANISM
Tape
Motor
Variable Resistor in motor
R336
R357
AM
LOOP
ANTENNA
IC302
T351
IC303
L354
T303
T306
CNP302
SO301
FE301
MAIN PWB-A1
TP302
TP301
AM TRACKING fL
AM BAND
COVERAGE fL
AM IF
ANTENNA
TERMINAL
Page of 64