Read Sharp XL-HP600 (serv.man10) Service Manual online
XL-HP600E
– 14 –
Standard Specification of Stereo System Error Message Display Contents
Error Contents
DISPLAY
Notes
CD
Pickup Mechanism Error.
'ER-CD**'
01: PU-IN SW Detection NG.
CD Changer Mechanism Error.
'ER-CD**'
10: Changer Error.
(*)
11: Initial Error.
CD DSP Communication Error
'ER-CD**'
31: DSP COMMUNICATION ERROR
Focus Not Match.
'NO DISC'
TUN
PLL Unlock.
FM
87.50
MHz
PLL Unlock.
(*) CHECKING:
If CD changer mechanism error is detected, 'CHECKING' will be display instead of 'ER-CD**' display 'ER-CD**' will only be display
when CD changer mechanism error had been detected for the 5 th times.
If CD changer mechanism error is detected, 'CHECKING' will be display instead of 'ER-CD**' display 'ER-CD**' will only be display
when CD changer mechanism error had been detected for the 5 th times.
Speaker abnormal detection and +B PROTECTION display
In case speaker abnormal detection or +B PROTECTION had occurred, it can be check by pressing 'POWER', 'VIDEO' and 'X-
BASS' key twice. Display will show "S** B**". S is referring to speaker abnormal detection and B is referring to +B PROTECTION.
** is in hex valve.
In case speaker abnormal detection or +B PROTECTION had occurred, it can be check by pressing 'POWER', 'VIDEO' and 'X-
BASS' key twice. Display will show "S** B**". S is referring to speaker abnormal detection and B is referring to +B PROTECTION.
** is in hex valve.
+B PROTECTION is condition when irregular process occur on power supply line.
Before transporting the unit
The following process need to be taken after set tapering/parts replacement.
1. Press the ON/STAND-BY button to enter stand-by mode.
2. While pressing down the
The following process need to be taken after set tapering/parts replacement.
1. Press the ON/STAND-BY button to enter stand-by mode.
2. While pressing down the
button and the X-BASS/DEMO button, press the ON/STAND-BY button until "CLEAR AL"appears.
3. While pressing down the
/
button and the X-BASS/DEMO button, press the ON/STAND-BY button until "WAIT
→
FINISHED" appears.
4. Unplug the AC cord and the unit is ready for transporting.
4. Unplug the AC cord and the unit is ready for transporting.