XL-560E (serv.man2) - Sharp Audio Service Manual (repair manual). Page 17

Read Sharp XL-560E (serv.man2) Service Manual online

– 17 –
XL-560H/E,570H/E
* When the "PRESET UP" button or "PRESET DOWN" button is pressed after completion, the following indication appears.
* If signal exists at 106.50 MHz, the following indication appears.
In case of memory storage with ASPM, for example, if RDS station 107.50 MHz has the PI code (the same as that of RDS
station 105.50 MHz) and VSM is greater than 105.50 MHz (PR-01), data is overwritten on 105.5 MHz which is contained in
"PR-01". (Frequency is changed to 107.50 MHz.)
If VSM is equal, previously stored 105.50 MHz remains.
When RDS station is stored in the test mode, the 2-second blinking of preset No. is not performed so as to save the production
line test time. ("RDS" lighting is performed.)
Note: RDS operation is performed in FM MONO state. However, in case of ASPM, ASPM scan is performed after BAND is
changed from FM MONO to FM STEREO.
Note: When the 
 (PLAY) button is pressed in TEST 2 mode, it is possible to check the sate of IF count. However, this
function is for designer. It is not necessary for other sections.
CH indication
(for 2 seconds)
Frequency indication
(for 2 seconds)
Time series indication of PS name indication is enabled.
(The same as in case of Ordinary)
NO PS
(Blinking for 5 seconds: 1 Hz)
Note: If PS is fixed after the frequency indication is
resumed, the PS name indication is restored.
FM 106.50 MHz
When the PS data is given in case of NO PS indication, the
PS name indication is restored.
PS name
Note: If PS is fixed after the frequency indication is
resumed, the PS name indication is restored.
NO PS
(Blinking for 5 seconds: 1 Hz)
Page of 64
Display

Click on the first or last page to see other XL-560E (serv.man2) service manuals if exist.