XL-515H (serv.man3) - Sharp Audio Service Manual (repair manual). Page 10

Read Sharp XL-515H (serv.man3) Service Manual online

XL-515H,515HR/CP-515
– 10 –
1. This CD unit need adjustment as follow.
CD SECTION
CD Test Mode
Adjustment Part
Value/Adjusting Method
Instrument Connection
Step 1
VR803 (Focus Offset)
DC + 40 mV (FEI>VRO)
FEI (R826) and VRO
(1-Pin of TP801)
Step 4
VR802 (Tracking Error Balance)
*1 (See Fig. 11-1)
TSO (3-Pin of TP801)
and VRO (1 Pin of TP801)
*1: Adjust to obtaiin vertically symmetrical waveform (Fig. 11-1) with respect toreference DC level. The reference level is VRO
(Approx DC 2.1V).
2. This CD unit have the following automatic adjustment function. Automatic adjustment item.
2-1: Focus Servo Gain (Fig. 11-2)
Focus Gain Adjustment is performed when disc is changed.
2-2: Tracking Servo Gain (Fig. 11-3)
Tracking Gain Adjustment is performed when disc is changed and disc is playbacked.
Figure 10-1 ADJUSTMENT POINTS
VR802
VR803
TP801
TRACKING
ERROR
BALANCE
FOCUS
OFFSET
T
S
O
N
C
V
R
O
321
3 2 1
CD SERVO PWB
   RDS
In order to receive RDS broadcasts, adjust the preset variable resistor as follows.
Adjust the center frequency of the 57 kHz BPF(band-pass filter) using the variable resistor (VR521).
Receiver: Connect the SG output to the aerial terminal.
It is not necessary to connect the speaker output terminal.
Set the frequency display to 98 MHz to tune in the 98 MHz frequency.
IC521
LA2232
C525
0.022
C524
0.01
VR521
4.7k
R521
1k
R523
6.8k
Done
Electric
Voltmeter
Apply 57 kHz, 50mV(ms)
to pin (6) of the input on 
LA2232.
Adjust the variable resistor 
(VR521) until you have the 
maximum value on the 
electric voltmeter.
Adjustment
point
Procedure
57 kHz
oscillator
Frequency
counter
Adjust the 57 kHz
oscillator before 
starting, so that 
the frequency 
counter reads 
57 kHz 
±
 6 Hz.
0.022
input
50mV
B.P.F
T.P
6
5
11
Page of 56