– 20 –
4.  Disc Loading Mechanism Test: CD MECHA Test
Purpose:
An operational check and aging test of disc loading mechanism
Functions: Manual control of a loading/mechanism up/down motor
Loading/eject control
Aging test with TOC reading
Aging test w/o TOC reading
Error display due to abnormal aging test results
Operation: By entering operations assigned only to this test mode, each mode processes its operation.
Manual control mode: Manually controls mechanism according to the operation entered.
  Normal and reverse rotations of a loading motor
  Normal and reverse rotations of a mechanism up/down motor
  Loading/eject control
Aging mode with TOC reading: Repeatedly performs loading/TOC reading/ejection.
  Displays number of times. Maximum test counts are 100,000.
Aging mode w/o TOC reading: Performs loading/ejection only to test mechanism aging.
   Displays number of times. Maximum test counts are 100,000.
Errors should be handled according to normal procedures.
Mode diagram:
By pressing the specified buttons, the unit enters the manual control mode and then the mechanism test mode.
Test mode initial display
"IX***V****"
Mode select display
"MECHA        "
Mechanism test manual 
control mode
"MECHA     :         "
Aging mode w/o TOC 
reading
"L/E  N000000"
Testing mechanism 
aging w/o TOC reading
"L/E  N                      "
Currently in the mechanism 
aging mode w/o TOC reading
"L/E  N                      "
Aging mode with TOC reading
"LIE  N000000"