– 97 –
SD-AT100H
WAVEFORMS OF 1-BIT CIRCUIT
T
2
1
2.00V/div
500ns/div
194.545465
µ
s
520mV
2.00V/div
AD IC Output
+ Side
- Side
5V
Amplitude
from 0 to 5 V
1
2
T
10.0V/div
500ns/div
194.545465
µ
s
-12.3V
10.0V/div
+SIDE
+FETOUT
- SIDE
Waveforms before low-pass filters at both 
ends of the speaker
H-bridge may be considered as BTL. 
However, here and at the gate drive, dead 
time is not observed; since bootstrap 
operates based on output, DEAD TIME 
part is in floating condition. The waveform 
on the HI GH side shows that only the 
booted voltage lowers. 
2
1
11
12
2
1
2.00V/div
500ns/div
194.545465
µ
s
-12.30V
2.00V/div
AD IC NF IN
In partial pressure OUT, 4 to 7 V amplitude 
of GND reference is observed.
In IC of 75 kohms, the reference is 2.5 V 
because of VREF. Due to imaginary GND 
of operational amplifier inside IC, the 
waveform cannot be monitored.
This waveform is partial pressure OUT.
3
4
T
2.00V/div
50.0ns/div
0.0s
-12.30V
2.00V/div
LEVEL SHIFT OUT
DEAD TIME
ZOOM UP
Dead time is generated by level 
shift input.  
Leading edge is delayed at CR, 
passing R at DI.
Set value: 20 -25 nsec
5
6
Page of 18