CD-SW300H (serv.man3) - Sharp Audio Service Manual (repair manual). Page 9

Read Sharp CD-SW300H (serv.man3) Service Manual online

CD-SW300H
2 – 2
[2] Test mode
 Setting the test mode
During stand-by mode, press GAME/VIDEO button
while pressing down the
button and
button.
then, press the CD button to enter the test mode.
IL isn’t done
OPEN/CLOSE operation is using manual.
IL isn’t done
<<
>>,<<
>>buttons make pick's slide possible.
IL isn’t done
                                            
to page 2-3
<<PLAY>> key input.
C D
T
E S T
A
Do TOC IL. Do normal play.
When these following key is input into PLAY key, track num-
ber can be appoint directly.
<<MEMORY>>
key input.
<<
1>> key: Track 4
<<
2>> key: Track 9
<<
3>> key: Track 15
Adjustment result automatically will
display as below for each 2 sec:
a) "FOF_XXXX"
b) "TOF_XXXX"
c) "TBAL_XX"
d) "TGAN_XX"
f) "FGAN_XX"
g) "RFLS_XX"
––––––––
<<STOP>> key input.
STOP
explanation:
a) Focus off set
= "FOF_XXXX"
b)Tracking off set
= "TOF_XXXX"
c)Tracking balance
= "TBAL_XX"
d)Tracking Gain
= "TGAN_XX"
f) Focus Gain
= "FGAN_XX"
g) RF level shift
= "RFLS_XX"
VOL — Last memory
P.GEQ — FLAT
X-BASS — OFF
To cancel : Power OFF