– 9 –
CD-E250E
CD-E550E
Figure 9-1
How to remove the flywheel (TAPE 1,2)
 (See Fig. 9-1.)
1. Remove the stop washer (H1) x 1 pc., with a small precision
screwdriver to extract the flywheel from the capstan metal.
Note:
When the stop washer is deformed or damaged, replace it
with a new one.
How to reinstall the parts
Install each part in the reverse order of the removal with care.
TAPE 1
TAPE 2
Stop
Washer
Driver
(H1)x1
Stop Washer
Mechanism
Chassis
Washerx2
Flywheel
How to remove the tape mechanism PWB
(TAPE 1,2)  (See Fig. 9-2.)
1. Remove the screw (J1) x 1 pc., to remove the tape
mechanism PWB.
2. Remove the screw (J2) x 1 pc.
3. Remove the solder joints (J3) x 2 pcs., to remove the tape
mechanism PWB.
Figure 9-2
TAPE 1,2
Tape 
Mechanism
PWB
Tape 
Mechanism
PWB
(J3)x2
Solder
Joint
(J2)x1
ø2x8mm
(J1)x1
ø2x3mm