Read Sharp AY-XP13CR (serv.man8) Service Manual online
20
AY-XP08CR
AY-XP10CR
AY-XP13CR
AY-XP10CR
AY-XP13CR
Clean
Contaminated
Determined
clean
clean
Determined
contaminated
contaminated
Reference
value
value
High (2 sec.)
Med (3 sec.)
Low (4 sec.)
Med (3 sec.)
Low (4 sec.)
15k
Ω
15k
Ω
13k
Ω
13k
Ω
R7
R6
(2) Dust detection by using the sensor
The output voltage from the optical allergen sensor is input into the indoor unitÅfs microcomputer to detect the air
contamination (dust). This method inputs the sensor voltage per unit of time and calculates the relative fluctuation
to determine whether the air is contaminated or not.
contamination (dust). This method inputs the sensor voltage per unit of time and calculates the relative fluctuation
to determine whether the air is contaminated or not.
(3) Operation of the indoor unit's microcomputer
As with the odor sensor, the microcomputer starts constantly detecting the air contamination level after 1 minute of
the operation start.
the operation start.
(4) Switching sensitivity of the optical allergen sensor
The sensitivity can be adjusted. However, both sensors will be adjusted
to the same level.
The air contamination is detected in the following seconds at each sensor
level.
to the same level.
The air contamination is detected in the following seconds at each sensor
level.
ECO
ECO
TIPS ABOUT INDICATOR PANEL
The indicator panel will change each time you press
the DISPLAY button in the following manner.
the DISPLAY button in the following manner.
The room temperature and
POWER MONITOR are displayed.
POWER MONITOR are displayed.
The outdoor temperature and
POWER MONITOR are displayed.
POWER MONITOR are displayed.
No display.
POWER MONITOR
When the room temperature or the outdoor temperature is displayed, the POWER MONITOR
will light up in 4 levels for COOL and HEAT modes (3 levels for DRY mode), to indicate the
operation power. When the air conditioner is operating at maximum power in the COOL and
HEAT modes, "Power" will light and "Eco" will turn off on the indicator panel.
will light up in 4 levels for COOL and HEAT modes (3 levels for DRY mode), to indicate the
operation power. When the air conditioner is operating at maximum power in the COOL and
HEAT modes, "Power" will light and "Eco" will turn off on the indicator panel.
NOTES:
• The displayed temperatures are rough estimates and may vary from the actual temperatures.
• Temperature display ranges
• Temperature display ranges
Room temperature: 0
°C ~ 40°C ( is displayed when less than 0°C and when higher
than 40
°C)
Outdoor temperature: -9
°C ~ 45°C ( is displayed when less than -9°C and when higher
than 45
°C)
•
is displayed during the first 90 seconds of operation while the temperatures are being
detected.
• Only the room temperature can be displayed for 5 seconds when the unit is not in operation.
Room Temp.
Lamp
Temperature
Indicator
POWER MONITOR
Outdoor Temp.
Lamp
DISPLAY
FULL
POWER