AY-XP13CR (serv.man8). Functions - Sharp Air Conditioner Service Manual (repair manual). Page 2

Read Sharp AY-XP13CR (serv.man8) Service Manual online

17
AY-XP08CR
AY-XP10CR
AY-XP13CR
1-6 OFF-timer
The OFF-timer is set by pressing the OFF-timer
button. Operation is as follows:
1-8 One-hour operation
If this button is pressed when operation is stopped,
operation will begin and then stop after 1 hour.
If pressed when it is operating, will stop after one
hour.
1-9 Full power operation
Immediately begins cooling or heating at maximum
power and air flow.
(During heating)
Operates at setting of 32 ˚C.
(During cooling)
Operates at setting of 18 ˚C.
1-10 Power ON start
If a jumper wire is inserted into the place indicated
JP99 on the indoor control board, and the circuit
breaker is turn ON. Coolng or heating will be
automatically determined by the room temperature
sensor on the main unit, and operation will begin.
1-11 Preheat
When heating is stopped, supplies a small amount
of power to the compressor to make heating start
more quickly. Operates when the indoor temperature
sensor and external air sensor detect that the room
temperature and outdoor temperature are low (below
18°C and 5°C, respectively). Stops when the
compressor chamber temperature rises above 25°C.
Preheat does not operate for 2 hours after heating
is stopped. After that, it goes on for 180 minutes
and then stops for 30 minutes, repeatedly.
1-12
Power selector [AY-XP13CR]
Operation power “H “ (High) or “L” (Low) can be
selected by switching the POWER SELECTOR
slide switch located above the AUX. button.
*During Heating
Cooling
Heating
Set temperature
By fuzzy computing
Set the shift up time
Cooling setting + 1
°C
Heating setting - 3
°C
Final
Dry
Same as above 
(Final setting + 1
°C)
*During Cooling / Dry
1-7 Swing louvre
The louvre is moved by a stepping motor to perform
swing and fixing in the set position.
If the "FLOW DIRECTION" button is pressed during
swing, it will stop. If the "FLOW DIRECTION" button
is pressed while it is stopped, it will swing.
The vertical adjustment louvre will change its angle
continuously.
Press the SWING button again when the vertical
adjustment louvre is at the desired position.
• The louvre will stop moving within the range shown
in the diagram.
• The adjusted position will be memorized and will
be automatically set to the same position when
operated the next time.
1
°C
Stops
Timer set time
1
hour
Timer operation starts
Room 
temperature
3
°C
Room 
temperature
Timer set time
1
hour
Timer operation starts
Stops
1-13
Auto Restart
When power failure occures, after power is
recovered, the unit will automatically restart in the
same setting which were active before the power
failure.
Operating mode (Cool, Heat, Dry)
 Temperature adjustment (within 2˚C range)
automatic operation
 Temperature setting
 Fan setting
 Air flow direction
 Power ON/OFF
 Automatic operation mode setting
 Swing louvre
Setting not memorized
 Timer setting
 Full power setting
COOL and DRY modes
HEAT and FAN ONLY mode
The adjustment range
is narrower the SWING
range in order to pre-
vent condensation from
dripping.
The range is wide so the
air flow  can be directed
toward the floor.
Adjustment range
Power 
select
Cooling
Heating
H
7.9A
10.5A
6.1A
7.2A
L
EWI130H
Page of 10