AY-XP08CR (serv.man12). Disassembly procedure - Sharp Air Conditioner Service Manual (repair manual). Page 26

Read Sharp AY-XP08CR (serv.man12) Service Manual online

26
AY-XP08CR
AY-XP10CR
AY-XP13CR
FUNCTION AND OPERATION OF PROTECTIVE PROCEDURES
Function
NO
Description
Detection 
time
Restart 
condition
Restart 
times
Indoor Outdoor
Operation
Self diagnostic
display
1
2
3
4
5
6
7
Indoor fan 
lock
Indoor fan 
rpm error
Indoor 
freezing 
guard
Indoor 
overheating 
control
DC 
overcurrent
AC 
overcurrent
Compressor 
overheating 
control
Compressor 
high 
temperature 
error
Stops operation if no rotation pulse signal 
is input from the indoor fan motor for one 
minute.
Stops operation if the rotation pulse signal 
from the indoor fan indicates low rpm 
(approximately 300 rpm or less).
Lowers the operating frequency if the 
temperature of the indoor heat exchanger 
goes below 5
°C during cooling. Stops the 
compressor if the temperature stays below 
0
°C for 4 minutes.
Lowers the operating frequency if the 
temperature of the indoor heat exchanger 
rises above the overheating temperature 
during heating. Stops the compressor if the 
temperature stays above the overheating 
temperature for 1 minute at minimum 
frequency or less.
Set values for overheating temperature
During normal operation: 45
°C to 54°C
During full power operation: 47
°C to 
58
°C
Stops the compressor if a current of 
approximately 23A or more flows in the 
power transistor module. 
Lowers the operating frequency if the 
compressor AC current exceeds 
set value(   ).Show "2-2(1)AC peak 
control"
Stops the compressor if the current 
exceeds at 40Hz or less set value(   ).
Lowers the operating frequency if the 
temperature of the compressor chamber 
thermistor (TH1) rises above 105
°C.
Stops the compressor if the thermistor 
stays above 105
°C for 1 minutes at 
minimum frequency or less.
Stops the compressor if the compressor 
chamber thermistor is above 114
°C.
(Or when TH1 shorts)
When indoor 
fan is rotation
During cooling 
and dry 
During heating
During 
compressor 
operation
During 
compressor 
operation
During 
compressor 
operation
During 
operation
Operation OFF
Automatically 
restarts when the 
exchange 
temperature rises 
above the freezing 
prevention 
temperature (above 
2
°C)
Automatically 
restarts when the 
exchange 
temperature goes 
below the 
overheating 
temperature.
Automatically 
restarts after safety 
time (170 seconds) 
Automatically 
restarts after safety 
time (170 seconds)
Automatically 
restarts after safety 
time (170 seconds)
Automatically 
restarts when 
thermistor (TH1) 
temperature falls 
below 100
°C 
(approximately 30 
after minutes)
No limit
No limit
No limit
8times
4 times
No limit
4 times
Yes
No
No
Yes
Yes
No
Yes
No
No
No
Yes
Yes
No
Yes
(   )
M o d e l
S e t  
v a l u e
C o o l
H e a t
6 . 2 A
6 . 7 A
5 . 3 A
5 . 4 A
7 . 9 A
1 0 . 5 A
A E - X 0 8 C R
A E - X 1 0 C R
A E - X 1 3 C R
Page of 48
Display

Click on the first or last page to see other AY-XP08CR (serv.man12) service manuals if exist.