Read Sharp AY-A244 Specification online
25
AY-A184E
AY-A244E
AE-A184E
AE-A244E
AY-A244E
AE-A184E
AE-A244E
Cycle temperature and service port pressure
ISO Cooling and heatpump condition
(at 220V refrigerant pipe length 7.5 m)
(at 220V refrigerant pipe length 7.5 m)
ISO
Cooling and Heatpump condition
Dimension of Capillary tube
For AY-A184E
For AY-A244E
O.D.
I.D.
L
Capillary tube A
Capillary tube B
Capillary tube C
o 3.5
o 2.7
o 2.4
o 2.4
o 0.8
900
600
1000
o 3.5
O.D.
I.D.
L
Capillary tube
o 3.2
o 1.9
600
AY-A184E
AY-A244E
Cooling
Cooling
Heating
Heating
Model
NO. Condition
1
2
3
4
Service port pressure
93˚C
84˚C
78˚C
88˚C
39˚C
45˚C
3˚C
1˚C
14˚C
16˚C
43˚C
42˚C
6˚C
8˚C
-3˚C
-2˚C
0.45MPa
0.47MPa
1.75MPa
1.90MPa
Indoor side
Outdoor side
Temperature (˚C)
Temperature (˚C)
Relative humididity (%)
Relative humididity (%)
27
48
35
40
20
37
7
87
Cooling
Heating
Click on the first or last page to see other AY-A244 service manuals if exist.