AY-A184 - Sharp Air Conditioner Specification (repair manual). Page 2

Read Sharp AY-A184 Specification online

2
AY-A184E
AY-A244E
AE-A184E
AE-A244E
SPECIFICATIONS
ITEMS
INDOOR UNIT
OUTDOOR UNIT
INDOOR UNIT
OUTDOOR UNIT
AY-A184E
AE-A184E
AY-A244E
AE-A244E
Cooling capacity
kW
5.1
6.7
Heatpump
kW
5.8
7.9
Heating capacity
Moisture removal
Liters/h
2.1
2.5
     Electrical data
Phase
Single
Rated frequency
Hz
50
Rated voltage range
V
198 to 264
Rated voltage
V
220 – 240
Rated current
Cool
A
9.3 – 9.7
12.9 – 13.6
Heat
A
9.2 – 9.8
12.5 – 13.5
Rated input
Cool
W
2010 – 2150
2680 – 2840
Heat
W
1950 – 2100
2640 – 2830
Power factor
Cool
%
98 – 92
94 – 87
Heat
%
96 – 89
96 – 87
Compressor
Type
Hermetically sealed rotary type
Model
SRC75BV1TN
PH330X3J-4MT
Oil charge
850cc (SUNISO 4GSD.I)
700cc (SUNISO 4GSD)
Refrigerant system
Evaporator
Louver fin and Grooved tube type(7mm tube)
Condenser
Louver fin and Grooved tube type
Control
Capillary tube
Refrigerant volume
1500 g(Factory charged)
1460 g(Factory charged)
De-lce system
Micro computer controled reverse sysetm
Noise level
High
dB(A)
44
53 – 54
46
56 – 56
(at cooling)
Med.
dB(A)
41
44
Low
dB(A)
39
41
Fan system
Drive
Direct drive
Air flow quantity
High
m
3
(cft)/min.
14.6(516)
42(1483)
16.5(583)
48(1694)
 (at cooling)
Med.
m
3
(cft)/min.
13.2(466)
14.9(527)
Low
m
3
(cft)/min.
11.2(396)
12.4(438)
Fan
Cross flow fan
Propeller fan
Cross flow fan
Propeller fan
Connections
Refrigerant coupling
Flare type
Refrigerant tube size Gas, Liquid
1/2", 1/4"
5/8", 1/4"
Refrigerant pipe sets No.
AZ-24H7F; 7m
Drain piping mm(Inches)
O.D  ø 20(50/64)
Others
Safety device
Compressor: Overload protector
Compressor: Internal protector
Fan motors: Thermal protector(Internal)
Fuse, Micro computer control
Air filters
Polypropylene net (Washable)
Net dimensions
Width
mm(Inches)
1100(43-5/16)
800(31-1/2)
1100(43-5/16)
800(31-1/2)
Height
mm(Inches)
330(13)
637(25-1/16)
330(13)
637(25-1/16)
Depth
mm(Inches)
195(7-11/16)
297(11-11/16)
195(7-11/16)
297(11-11/16)
Net weight
kg
13
51
14
59
 Note: The condition of star (     ) marked item are ‘IEC378’.
Page of 44