AU-M188 - Sharp Air Conditioner Service Manual (repair manual). Page 24

Read Sharp AU-M188 Service Manual online

24
AH-M098E
AU-M188E
5
2
3
4
1
5
7
8
Control cover ass'y
Base pan ass'y
Condenser
Running 
capacitor
Fan motor capacitor
Control box
Cabinet
Compressor
Fan motor
Propeller fan
Fan guard
Left side plate
6
OUTDOOR UNIT
CAUTION:DISCONNECT THE UNIT FROM THE POWER SUPPLY BEFORE ANY SERVICING
1. Remove the screw holding the left side plate and pull it
out.
2. Remove the one screw holding the control cover to the
cabinet and pull it out.
3. Loosen the screw holding the right side plate.
4. Remove the another screw holding the right side plate
and pull it out.
5. Remove the screws holding the left and right side of
the cabinet.
6. Lift up and remove the cabinet.
7. Remove the one nut holding the fan to the fan motor
shaft, now the fan is free.
8. Remove the three screws holding the fan motor to
the motor stay sngle , now the fan motor is free.
NOTE:     Number shown in follwing figure are
the removal order.
Figure D-2. OUTDOOR UNIT MODEL AU-M188E
Page of 32