Read Sharp MX-2610N / MX-3110N / MX-3610N (serv.man179) Technical Bulletin online
CCE 1008
* Regarding the “ROM UPGRADE (7)” which is notified in T/R No. CCE-1008 issued on
April 9, 2012, the information on “SIM55-3” was missing among the additional Soft SW
1. Model Name:
MX-2610N/3110N/3610N (Except for China/Taiwan)
2. Description:
Upgrade of ICU, PCL, PCU-ROM, and E-Manual
From mid-March 2012 production
ROM control No.
ICU
PCL
PCU
SCU
FAX
E-Manual
G00
0600A1 0600A1 0303G1 0107G1 0101G1 0180A1
* ICU above is the version described in the ROM management label. Check that the actual
version is: ICU(MAIN): 06.00.A1.00/ICU(BOOT): 01.00.A1.0c/ICU(SUB): 01.03.A1.00/
LANGUAGE: 01.59.A1.00/GRAPHIC: 01.00.A1.00/UICONTENTS: 06.00.A1.00 by SIM22-5.
* PCL above is also the version described in the ROM management label. Check that the
actual
version is: PCL (MAIN): 06.00.A1.00/PCL (PROFILE): 01.00.A1.00; by SIM22-5.
version is: ICU(MAIN): 06.00.A1.00/ICU(BOOT): 01.00.A1.0c/ICU(SUB): 01.03.A1.00/
LANGUAGE: 01.59.A1.00/GRAPHIC: 01.00.A1.00/UICONTENTS: 06.00.A1.00 by SIM22-5.
* PCL above is also the version described in the ROM management label. Check that the
actual
version is: PCL (MAIN): 06.00.A1.00/PCL (PROFILE): 01.00.A1.00; by SIM22-5.
Item of change : See the attached sheet
ROM version combination history table
No
ROM
control No.
ICU PCL PCU SCU FAX
E-Manual
Action
T/R
No
(6)
F00
0500A1 0500A1 0302G1 0107G1 0100G1 0170A1 2011/12
Mid
CCE-993
(5)
E00
0400A1 0400A1 0301G1 0107G1 0100G1 0161A1 2011/9
Mid CCE-960
(4)
D00
0300A1 0300A1 0300G1 0106G1 0100G1 0150A1 2011/7
Mid CCE-941
(3)
C00
0200A1 0200A1 0201G1 0105G1 0100G1 0130A1 2011/5
Mid CCE-918
(2)
B00
0110A1 0108A1 0111G1 0103G1 0100G1 0122A1 2011/3
Mid CCE-894
(1)
A16
0106A1 0101A1 0109G1 0103G1 0100G1 0122A1 2011/2
Mid CCE-883
ROM UPGRADE ..... (7).
TECHNICAL BULLETIN
Date: April 9
th
2012
Model: MX2610-3610
Ref: CCE-1008R
Colour: White
Ref: CCE-1008R
Colour: White
Page: 1 OF 4
CCE 1008
[Description]
No. Item
Details
1 UI
The feature that the [X] keys indicating the determination of the setting can be
changed to the [OK] keys has been added to the SOFT SW.
* As for the [X] keys indicating [Cancel] and [Close], no change has been made.
SIM55-3 SW No. 28 Data 7
0: Disable
1: Enable (Default)
changed to the [OK] keys has been added to the SOFT SW.
* As for the [X] keys indicating [Cancel] and [Close], no change has been made.
SIM55-3 SW No. 28 Data 7
0: Disable
1: Enable (Default)
2 UI
The feature not to use the [Multi Shot], [Pamphlet] functions when reprinting the
print data stored using the retention function has been added to the SOFT SW.
SIM55-3 SW No. 28 Data 6
0: Disable (Default)
1: Enable
print data stored using the retention function has been added to the SOFT SW.
SIM55-3 SW No. 28 Data 6
0: Disable (Default)
1: Enable
3 UI
Only when the destination is just one, the feature that the address and the scan
condition can be retained for a certain period of time with the Scan To Desktop
function has been added to the SOFT SW.
SIM55-3 SW No. 27 Data 8
0: Disable (Default)
1: Enable
condition can be retained for a certain period of time with the Scan To Desktop
function has been added to the SOFT SW.
SIM55-3 SW No. 27 Data 8
0: Disable (Default)
1: Enable
4 UI
When specifying the [Envelop] as the paper type for the bypass tray, the feature
that the screen will automatically be changed to the size tab screen has been
added to the SOFT SW.
SIM55-3 SW No. 28 Data 4
0: Disable (Default)
1: Enable
that the screen will automatically be changed to the size tab screen has been
added to the SOFT SW.
SIM55-3 SW No. 28 Data 4
0: Disable (Default)
1: Enable
5 UI
When detecting the Legal sized original with the scan function, the feature that the
setting value of "Image Orientation" of the original screen will automatically be set
to the short edge being placed to the leading edge side has been added to the
SOFT SW.
(If the setting is manually switched by the user, that manual setting will be
prioritized.)
SIM55-3 SW No. 28 Data 5
0: Disable (Other)
1: Enable (USA/CANADA)
setting value of "Image Orientation" of the original screen will automatically be set
to the short edge being placed to the leading edge side has been added to the
SOFT SW.
(If the setting is manually switched by the user, that manual setting will be
prioritized.)
SIM55-3 SW No. 28 Data 5
0: Disable (Other)
1: Enable (USA/CANADA)
6 UI
Modification has been made to operate as the setting of "Display Action Panel as
default" also on the "Job Status Screen".
default" also on the "Job Status Screen".
7 UI
The design of the tab being selected on the setting screen has been changed to
make it easier to understand that it is the selected tab.
make it easier to understand that it is the selected tab.
8 UI
Modification has been made to change the screen automatically to the concerned
job mode if the registered job mode is only one type when the shortcuts are set up
for Program (only in Image Send mode)/Contacts/Group on Home screen.
job mode if the registered job mode is only one type when the shortcuts are set up
for Program (only in Image Send mode)/Contacts/Group on Home screen.
9 UI
Modification has been made to display the following message prompting for the
service call as below if the icon displayed in the system area is pressed when the
IC card reader connection trouble occurs.
"IC card reader is not recognized. Check the connection of IC card reader. If the
problem cannot be fixed, call for service"
service call as below if the icon displayed in the system area is pressed when the
IC card reader connection trouble occurs.
"IC card reader is not recognized. Check the connection of IC card reader. If the
problem cannot be fixed, call for service"
10 UI
If the paper types/paper sizes that could not be output as the offset was selected
when setting up the Offset, it used to be that "The paper in the selected tray
cannot be used for the selected mode" message would be displayed and the
resume print was blocked as a specification. Now it has been modified to clear the
offset processing automatically when executing the job. (no message is displayed)
when setting up the Offset, it used to be that "The paper in the selected tray
cannot be used for the selected mode" message would be displayed and the
resume print was blocked as a specification. Now it has been modified to clear the
offset processing automatically when executing the job. (no message is displayed)
CCE 1008
11 UI
If the non-standard size was programmed as the original size with the Repeat
Layout function, the "Setting is not completed" message would be displayed when
calling up the program. This problem has been corrected.
Layout function, the "Setting is not completed" message would be displayed when
calling up the program. This problem has been corrected.
No. Item
Details
12 UI
When creating a new button with a long name like 3 lines long as the scan
destination, the operation panel would be hang up when pressing the concerned
button. This problem has been corrected.
destination, the operation panel would be hang up when pressing the concerned
button. This problem has been corrected.
13 UI
When selecting the program list of the Image Send, in some cases, it took a long
time to switch the screen. This process has been improved.
time to switch the screen. This process has been improved.
14 Printer
When printing, the gradation area of the image might become the dot-like. This
problem has been corrected.
problem has been corrected.
15 Printer
When printing with PS driver, the drawing position when the print mode was set to
"Normal" and "High quality" was different from the position when it was set to
"Fine". This problem has been corrected.
"Normal" and "High quality" was different from the position when it was set to
"Fine". This problem has been corrected.
16 Printer
When performing the Direct Print for the certain PDF file, in some cases, the
characters were missing.
This problem has been corrected.
characters were missing.
This problem has been corrected.
17 Printer
When performing the Direct Print for the certain JPEG file, in some cases, 2 pages
were printed for 1file. This problem has been corrected.
were printed for 1file. This problem has been corrected.
18 Printer
When printing with the combination of the Pamphlet function and feeding from the
bypass tray, if the paper was emptied in the bypass tray, in some cases, the
machine would not resume printing even though the paper was added. This issue
has been corrected.
bypass tray, if the paper was emptied in the bypass tray, in some cases, the
machine would not resume printing even though the paper was added. This issue
has been corrected.
19 Printer
The feature to set the printable area to the same level as the previous models has
been added to the controller SOFT SW.
SIM55-3 SW No. 27 Data 7
0: MX-2310 series/2610 series/3610 series/4110 series/5110 series Spec (Default)
1: MX-2600 series/3100 series/4100 series/5001 series Spec
been added to the controller SOFT SW.
SIM55-3 SW No. 27 Data 7
0: MX-2310 series/2610 series/3610 series/4110 series/5110 series Spec (Default)
1: MX-2600 series/3100 series/4100 series/5001 series Spec
20 Printer
If printing from the certain CAD software when using the external accounting
software, in some cases, MFP would hang up. This issue has been corrected.
software, in some cases, MFP would hang up. This issue has been corrected.
21 Printer
When printing the job containing the MACRO data from SAP, in same cases,
unnecessary characters would be printed at the head of each page. This problem
has been corrected.
unnecessary characters would be printed at the head of each page. This problem
has been corrected.
22 Network
Modification has been made not to finalize the IP address until the IP information
is obtained from DHCP server when the setting of DHCP is enabled.
is obtained from DHCP server when the setting of DHCP is enabled.
23 Network
When accessing to the file server with the sever name, in some cases, Scan to
Network Folder would be unusable. This problem has been corrected.
Network Folder would be unusable. This problem has been corrected.
24 Network
When the application communication kit (MX-AMX2) was equipped, if the
communication with the external server was disconnected under the condition
that the [Forward to Application] setting in [Receiving Application Setting] was set
to "Enable", the Fax job would be deleted without being output. This problem has
been corrected.
communication with the external server was disconnected under the condition
that the [Forward to Application] setting in [Receiving Application Setting] was set
to "Enable", the Fax job would be deleted without being output. This problem has
been corrected.
25 FAX
When receiving the FAX, in some cases, the receiving error: NG17-0000 occurred.
This problem has been corrected.
This problem has been corrected.
26 FAX
When 3 Lines expansion kit was connected, if the Line1 was disabled and the Auto
Line was selected, the data was sent with the Line1 even though it was disabled.
This problem has been corrected.
Line was selected, the data was sent with the Line1 even though it was disabled.
This problem has been corrected.
27
Main unit
Control
Control
The modification has been made not to largely change from the previous value by
setting up the limitation on the range which can change from the previous value
when executing the auto registration adjustment.
In conjunction with this measure, the modification has been made to start the
adjustment from the center value when executing the forced registration
adjustment.
setting up the limitation on the range which can change from the previous value
when executing the auto registration adjustment.
In conjunction with this measure, the modification has been made to start the
adjustment from the center value when executing the forced registration
adjustment.
28
Main unit
Authentication
Authentication
With the setting of IC card or the manual log-in by the manual input, using the
LDAP Authentication, if you attempted the manual log-in by the manual input after
LDAP Authentication, if you attempted the manual log-in by the manual input after
CCE 1008
the IC card was authenticated, in some cases, the card ID was recorded in the job
log even though it was the manual input. This problem has been corrected.
log even though it was the manual input. This problem has been corrected.
29
Main unit
Authentication
Authentication
With the setting of IC card or the manual log-in by the manual input, using the
LDAP Authentication, if you attempted the manual log-in by the manual input when
LDAP server was down, in some cases, the "Authentication is succeeded"
message would be displayed even though it was the manual input. This problem
has been corrected.
LDAP Authentication, if you attempted the manual log-in by the manual input when
LDAP server was down, in some cases, the "Authentication is succeeded"
message would be displayed even though it was the manual input. This problem
has been corrected.
30
Main unit
Authentication
Authentication
With the setting of IC card or the manual log-in by the manual input, using the
LDAP Authentication, if you attempted the manual log-in by the manual input, in
some cases, it would fail. This problem has been corrected.
LDAP Authentication, if you attempted the manual log-in by the manual input, in
some cases, it would fail. This problem has been corrected.
No. Item
Details
31 Web
Page
When the "Sys Log" in the Service Web Page was set to "Enable", in some cases,
the U2 error was caused by the execution of Reboot from the Web Page. This
problem has been corrected.
the U2 error was caused by the execution of Reboot from the Web Page. This
problem has been corrected.
32 Trouble
Code
The U2 trouble that should not have been cleared unless SIM16 was executed
could be cleared by the power-OFF/ON. This problem has been corrected.
(If the corrective firmware for this issue is installed to the machine that U2 trouble
was cleared only by the power-OFF/ON, the U2 trouble will be displayed when the
machine is turned ON after the completion of the installation so the appropriate
process to clear the U2 trouble will be required.)
could be cleared by the power-OFF/ON. This problem has been corrected.
(If the corrective firmware for this issue is installed to the machine that U2 trouble
was cleared only by the power-OFF/ON, the U2 trouble will be displayed when the
machine is turned ON after the completion of the installation so the appropriate
process to clear the U2 trouble will be required.)
33 Trouble
Clear
For the POD1_N jam, the modification has been made not to clear the jam unless
you open the right door. (Jam cannot be cleared by the power-OFF/ON)
you open the right door. (Jam cannot be cleared by the power-OFF/ON)
34 E-mail
RIC
At the timing of sending the Alert Mail of E-mail RIC, the mode to prevent more
than one Alert Mails of the same event from being sent out when warming up from
the Energy Save has been added to the controller Soft SW.
SIM55-3 SW No. 28 Data 3
0: Allowed: Current operation (Default)
1: Not Allowed
than one Alert Mails of the same event from being sent out when warming up from
the Energy Save has been added to the controller Soft SW.
SIM55-3 SW No. 28 Data 3
0: Allowed: Current operation (Default)
1: Not Allowed
35 Option
When using OSA application, the output trays which should be unable to use were
selectable. This problem has been corrected.
selectable. This problem has been corrected.