AU-A129 - Sharp Air Conditioner Service Manual (repair manual). Page 2

Read Sharp AU-A129 Service Manual online

AH-A129E
AU-A129E
2
SPECIFICATIONS
ITEMS
INDOOR UNIT
OUTDOOR UNIT
AH-A129E
AU-A129E
Cooling capacity
kW
3.45
Moisture removal
Liters/h
1.3
 Electrical data
Phase
Single
Rated frequency
Hz
50
Rated voltage range
V
198 to 264
Rated voltage
V
220 - 240
Rated current
Cool
A
5.3 - 5.1
Rated input
Cool
W
1150 - 1180
Compressor
Type
Hermetically sealed rotary type
Model
RH207VXET
Oil charge
520cc (DIAMOND MS56))
Refrigerant system
Evaporator
Louver fin and Grooved tube type(7mm tube)
Condenser
Louver fin and Grooved tube type(7mm tube)
Control
Capillary tube
Refrigerant volume
940g
Capillary tube size
Outer dia. mm
2.7
Inner dia. mm
1.6
Lenght
mm
700
Q'ty
1
Noise level
High
dB(A)
42
48
Med.
dB(A)
40
Low
dB(A)
36
Fan system
Drive
Direct drive
Direct drive
Air flow quantity
High
m
3
/min.
9.3
26
 (at cooling)
Med.
m
3
/min.
8.4
Low
m
3
/min.
7.0
Fan
Cross flow fan
Propeller fan
Connections
Refrigerant coupling
Flare type
Refrigerant tube size Gas, Liquid
1/2", 1/4"
Refrigerant pipe sets No.
AZ-24T7F; 7m(23ft)
Drain piping mm(Inches)
O.D  ø 18(45/64)
Others
Safety device
Compressor: Overload protector(Internal)
Fan motors: Thermal fuse
Fuse, Micro computer control
Air filters
Polypropylene net (Washable)
Net dimensions
Width
mm
897
720
Height
mm
297
535
Depth
mm
186
236
Net weight
kg
10
35
 Note: The condition of star(   ) marked item are 'IEC378'.
Page of 28
Display

Click on the first or last page to see other AU-A129 service manuals if exist.